../../images-webp/ce8c73b48c9223acfb7ac6dbb41c89dd.webp

Rexroth directional control valve, R901278744=4WE10J5X/EG24N9K4/M

LEHIY item code: LH-0370

Industrial valve for flow control applications. series WE.

Quick buying check

This page helps you check Rexroth directional control valve, R901278744=4WE10J5X/EG24N9K4/M before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

Product Overview

The WE model directional valve is a solenoid-coil-operated directional slide valve, which can be used as a solenoid ...


The WE model directional valve is a solenoid-coil-operated directional slide valve, which can be used as an electromagnetic component. This valve controls the start, stop, and direction of fluid flow.

Product Features

  • Specification 10

  • Component Series 5X

  • Maximum Working Pressure 350 bar

  • Maximum Flow Rate 160 l/min

  • Three-position four-way, two-position four-way or two-position three-way models

  • Port mounting surface conforms to ISO4401-05-04-0-05

  • High power coil, optional 90° rotation

  • Electrical connection as single or center-pair connection

  • Optional with PWM Connector (Quick-Switching Amplifier, Energy Saving) for Use

  • Auxiliary Operating Device, Optional

  • CE Compliance with Low Voltage Directive 2014/35/EU when voltage > 50VAC or > 75 VDC

  • Electromagnetic Coil is an Approved Component with UR Marking, Optional

  • Certified by CSA C22.2 no. 139-13, Optional

Technical Specifications

Specifications

10

Size



Einzelanschluss

Zentralanschluss

Valve with one coil

kg

3.9

4

Valve with two coils

kg

5.5

5.6

Installation Location 1)


Any

Ambient Temperature Range

NBR Seal

°C

-20…+70

FKM Seal

°C

-15…+70

HFC Hydraulic Oil

°C

-20…+50

Low Temperature Form 2)

°C

-40…+50

Storage Temperature Range

°C

-20…+50

MTTFD value conforms to ENISO138493)

Year

300

Maximum working pressure

Oil port P

bar

350

Oil port A

bar

350

Oil port B

bar

350

Interface T1)2)

bar

210

Maximum Flow Rate

DC Voltage

l/min

160

AC Voltage

l/min

120

Flow Cross-Section (Valve Core Position 0)

Symbol Q


Approximately 6% of the nominal profile

Symbol W


Approximately 3% of the nominal profile

Hydraulic oil


Please refer to the table "Hydraulic oil"

Hydraulic oil temperature range 3)

NBR seals

°C

-20…+80

FKM Seals

°C

-15…+80

HFC Hydraulic Oil

°C

-20…+50

Low Temperature Form

°C

-40…+50

Viscosity Range

mm²/s

2.8…500

Maximum permissible contamination level of hydraulic oil, conforming to cleanliness level 4 as specified in ISO 4406(c)


Level 20/18/15

Selection Guide SelectionData

01

02

03

04

05


06

07

08

09

10

11


12

13

14

15

16

17


WE

10


5X

/


E





/






*

mm

01

3 main oil ports

3

4 main oil ports

4

02

Directional valve

WE

03

Specification 10

10

04

Symbol; see "Symbol/Circuit Diagram" for available models

For example C

05

Component Series 50 … 59 (50 … 59: Mounting and Connection Dimensions Remain the Same)

5X

06

With Spring Return

No Code

With Reinforced Compression Spring (for Quick Closure)

D

Without spring return

O

Without spring return, with positioner

OF1)

07

High power coil, wet pin, with removable coil

E

Voltage

08

For order codes, please refer to the following... "Electrical connections and available voltage".

For example G24

Auxiliary control device

2)

09

Without manual emergency operation

No code

WithLockable manual emergency operation "mushroom button" (large)

N51; 3)

WithManual emergency operation "mushroom button" (large), not lockable

N61)

With Implicit Manual Emergency Operation and Protective Cap

N81; 4)

With Implicit Manual Emergency Operation (Standard)

N9

Corrosion Resistance (External) (See table below for availability)

10

None (Valve body primed)

None code

Improved corrosion resistance (tested 240 hours salt spray, conforms to EN ISO 9227) (see also "Technical Data")

J3

Electrical connection

11

Single connection or central connection

For ordering codes, see "Electrical Connections and Available Voltages" below.

For example, K4

Increased switching time

12

None Increased switching time

No code

YesIncreased switching time (only for symbol ".73"; not for model "D" with reinforced compression spring; more information available upon request)

A12

13

Without throttling plug-in (standard)

No code

With throttling plug-in (when exceeding the allowed valve performance limits, see "Performance Limits"):

5)


Connection

Throttling valve diameter in mm

0.8 mm

1.0 mm

1.2 mm

2.0 mm

3.0 mm

4,0 mm

P

B08

B10

B12

B20

B30

B40

A

H08

H10

H12

H20

H30

H40

B

R08

R10

R12

R20

R30

R40

A and B

N08

N10

N12

N20

N30

N40

T6)

X08

X10

X12

X20

X30

X40

Control valve core clearance

14

Standard (Recommended)

No code

Minimum (can be used to reduce leakage values; requires higher oil cleanliness)

T06

Increase (can be used for high temperature differential hydraulic oil/environment; results in higher internal leakage values)

T12

Seal material (Please ensure compatibility between the seal and the hydraulic oil used; see "Technical Data")

15

NBR Seals

M

FKM Seals

V

Recommended for use with HFC hydraulic oil

MH

Low Temperature Model (Only applicable to models without manual emergency operation)

MT

16

Standard

No Code

Certified by CSA C22.2 no. 139-13

CSA

Oil port mounting surface, compliant with ANSI B93.9

AN7)

17

More details given in plain text

*

Product Dimensions

DC Voltage - Single connection

Size in mm

Required surface quality for valve contact surface

1

Coil “a”

2

Coil “b”

7

Without connector "K4" and "K4K" line connector plug (order separately, see "Accessories")

8

Connector plug, right angle, M12x1 connector with connector "K72L" and status LED (order separately, see "Accessories")

9

Dual connector plug with/without connector "K4" line (order separately, see "Accessories")

10

Connector plug with connector "C4Z" (AMP Junior Timer) (order separately, see "Accessories")

11

Connector plug with "K4" connector (order separately, see "Accessories")

16

Nameplate

17

Oil ports A, B, P, TA, and TB have the same sealing ring

18

Protective plug for valve with a coil on side B

19

Protective plug for valve with a coil on side A

20

Space required to remove the connector plug/right-angle socket

21

Space required to remove the coil

22

Installing nut, tightening torque MA=14.5±1.5Nm

23

Oil port mounting surface conforms to ISO4401-05-04-0-05

24

When connecting to additionally machined holes, only connector TB can be used.

DC Voltage - Centering Connection

Dimensions in mm

Required Surface Quality for Valve Contact Surface

6

Cover
Note: The valve can only be operated when the cover is correctly installed.

12

Cable Bundle Coils "DL" and "DAL"

13

Central Connection Components "DK6L" and "DK25L"

14

Connecting Plug for Valves with Center Connection and Connector "DK6L" (Order separately, see "Accessories")

15

Small Exchange Connector "DK25L", 5-Pole (Order separately, Part No. R900057631)

20

Space required to remove the connector plug/right-angle socket

22

Installing nut, tightening torque MA=14.5±1.5Nm

23

Oil port mounting surface conforms to ISO4401-05-04-0-05

24

When connecting to additionally machined holes, only connector TB can be used.

DC Voltage - Manual Emergency Operation

Dimensions in mm

Required Surface Quality for Valve Contact Surface

3

Without and with Implicit Manual Emergency Operation "N9" (Standard)

4

With hidden manual emergency operation and protective cap "N8". (The protective cap must be removed before operation.)

5

Manual emergency operation "Mushroom Button" "N5" and "N6" can be locked

AC voltage - single connection

Dimensions in mm

Required surface quality for valve contact surface

1

Coil “a”

2

Coil “b”

3

Without and with Implicit Manual Emergency Operation “N9” (Standard)

7

Connector plugs without connector “K4” and “K4K” lines (order separately, see “Accessories”)

11

With connector “K4” Connection plug for the line (order separately, see "Accessories")

16

Nameplate

17

Oil ports A, B, P, TA and TB have the same sealing ring

18

Protective plug for valve with a coil on side B

19

Protective plug for valve with a coil on side A

20

Space required to remove the connector plug/right-angle socket

21

Space required to remove the coil

23

Oil port mounting surface conforms to ISO4401-05-04-0-05

24

When connecting to additionally machined holes, only connector TB can be used.


AC Voltage - Centering Connection


Dimensions in mm

Required Surface Quality for Valve Contact Surface

TB.

3

Without and with Implicit Manual Emergency Operation "N9" (Standard)

6

Cover
Note: The valve can only be operated when the cover is correctly installed.

12

Cable Bundle Coils "DL" and "DAL"

13

Central Connection Components "DK6L" and "DK25L"

14

Connecting Plug for Valves with Center Connection and Connector "DK6L" (Order separately, see "Accessories")

15

Small Exchange Connector "DK25L", 5-Pole (Order separately, Part No. R900057631)

20

Space required to remove the connector plug/right-angle socket

21

Space required to remove the coil

22

Installing nut, tightening torque MA=14.5±1.5Nm

23

Oil port mounting surface conforms to ISO4401-05-04-0-05

24

When connecting to additionally machined holes, only connecting...

Technical Specifications

SpecificationValue
BrandBosch Rexroth
SeriesWE
CategoryDirectional Control Valve

Plain language sourcing guide for Rexroth directional control valve, R901278744=4WE10J5X/EG24N9K4/M

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:RexrothCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

Rexroth directional control valve, R901278744=4WE10J5X/EG24N9K4/M

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

Rexroth directional control valve, R901278744=4WE10J5X/EG24N9K4/M verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo
fusheng logo