Rexroth directional control valve, R901278744=4WE10J5X/EG24N9K4/M
LEHIY item code: LH-0370
Quick buying check
This page helps you check Rexroth directional control valve, R901278744=4WE10J5X/EG24N9K4/M before you ask for a quote.
Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.
LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.
Product Overview
The WE model directional valve is a solenoid-coil-operated directional slide valve, which can be used as a solenoid ...
The WE model directional valve is a solenoid-coil-operated directional slide valve, which can be used as an electromagnetic component. This valve controls the start, stop, and direction of fluid flow. |
Product Features
|
Technical Specifications
Specifications | 10 | |||
Size | Einzelanschluss | Zentralanschluss | ||
Valve with one coil | kg | 3.9 | 4 | |
Valve with two coils | kg | 5.5 | 5.6 | |
Installation Location 1) | Any | |||
Ambient Temperature Range | NBR Seal | °C | -20…+70 | |
FKM Seal | °C | -15…+70 | ||
HFC Hydraulic Oil | °C | -20…+50 | ||
Low Temperature Form 2) | °C | -40…+50 | ||
Storage Temperature Range | °C | -20…+50 | ||
MTTFD value conforms to ENISO138493) | Year | 300 |
Maximum working pressure | Oil port P | bar | 350 |
Oil port A | bar | 350 | |
Oil port B | bar | 350 | |
Interface T1)2) | bar | 210 | |
Maximum Flow Rate | DC Voltage | l/min | 160 |
AC Voltage | l/min | 120 | |
Flow Cross-Section (Valve Core Position 0) | Symbol Q | Approximately 6% of the nominal profile | |
Symbol W | Approximately 3% of the nominal profile | ||
Hydraulic oil | Please refer to the table "Hydraulic oil" | ||
Hydraulic oil temperature range 3) | NBR seals | °C | -20…+80 |
FKM Seals | °C | -15…+80 | |
HFC Hydraulic Oil | °C | -20…+50 | |
Low Temperature Form | °C | -40…+50 | |
Viscosity Range | mm²/s | 2.8…500 | |
Maximum permissible contamination level of hydraulic oil, conforming to cleanliness level 4 as specified in ISO 4406(c) | Level 20/18/15 |
Selection Guide SelectionData
01 | 02 | 03 | 04 | 05 | 06 | 07 | 08 | 09 | 10 | 11 | 12 | 13 | 14 | 15 | 16 | 17 | ||
WE | 10 | 5X | / | E | / | * |
01 | 3 main oil ports | 3 | ||||
4 main oil ports | 4 | |||||
02 | Directional valve | WE | ||||
03 | Specification 10 | 10 | ||||
04 | Symbol; see "Symbol/Circuit Diagram" for available models | For example C | ||||
05 | Component Series 50 … 59 (50 … 59: Mounting and Connection Dimensions Remain the Same) | 5X | ||||
06 | With Spring Return | No Code | ||||
With Reinforced Compression Spring (for Quick Closure) | D | |||||
Without spring return | O | |||||
Without spring return, with positioner | OF1) | |||||
07 | High power coil, wet pin, with removable coil | E | ||||
Voltage | ||||||
08 | For order codes, please refer to the following... "Electrical connections and available voltage". | For example G24 | ||||
Auxiliary control device 2) | ||||||
09 | Without manual emergency operation | No code | ||||
WithLockable manual emergency operation "mushroom button" (large) | N51; 3) | |||||
WithManual emergency operation "mushroom button" (large), not lockable | N61) | |||||
With Implicit Manual Emergency Operation and Protective Cap | N81; 4) | |||||
With Implicit Manual Emergency Operation (Standard) | N9 | |||||
Corrosion Resistance (External) (See table below for availability) | ||||||
10 | None (Valve body primed) | None code | ||||
Improved corrosion resistance (tested 240 hours salt spray, conforms to EN ISO 9227) (see also "Technical Data") | J3 | |||||
Electrical connection | ||||||
11 | Single connection or central connection | |||||
For ordering codes, see "Electrical Connections and Available Voltages" below. | For example, K4 | |||||
Increased switching time | ||||||
12 | None Increased switching time | No code | ||||
YesIncreased switching time (only for symbol ".73"; not for model "D" with reinforced compression spring; more information available upon request) | A12 | |||||
13 | Without throttling plug-in (standard) | No code | ||||
With throttling plug-in (when exceeding the allowed valve performance limits, see "Performance Limits"): 5) | ||||||
Connection | Throttling valve diameter in mm | |||||
0.8 mm | 1.0 mm | 1.2 mm | 2.0 mm | 3.0 mm | mm 4,0 mm | |
P | B08 | B10 | B12 | B20 | B30 | B40 |
A | H08 | H10 | H12 | H20 | H30 | H40 |
B | R08 | R10 | R12 | R20 | R30 | R40 |
A and B | N08 | N10 | N12 | N20 | N30 | N40 |
T6) | X08 | X10 | X12 | X20 | X30 | X40 |
Control valve core clearance | ||||||
14 | Standard (Recommended) | No code | ||||
Minimum (can be used to reduce leakage values; requires higher oil cleanliness) | T06 | |||||
Increase (can be used for high temperature differential hydraulic oil/environment; results in higher internal leakage values) | T12 | |||||
Seal material (Please ensure compatibility between the seal and the hydraulic oil used; see "Technical Data") | ||||||
15 | NBR Seals | M | ||||
FKM Seals | V | |||||
Recommended for use with HFC hydraulic oil | MH | |||||
Low Temperature Model (Only applicable to models without manual emergency operation) | MT | |||||
16 | Standard | No Code | ||||
Certified by CSA C22.2 no. 139-13 | CSA | |||||
Oil port mounting surface, compliant with ANSI B93.9 | AN7) | |||||
17 | More details given in plain text | * |
Product Dimensions
DC Voltage - Single connection Size in mm |
Required surface quality for valve contact surface |
1 | Coil “a” |
2 | Coil “b” |
7 | Without connector "K4" and "K4K" line connector plug (order separately, see "Accessories") |
8 | Connector plug, right angle, M12x1 connector with connector "K72L" and status LED (order separately, see "Accessories") |
9 | Dual connector plug with/without connector "K4" line (order separately, see "Accessories") |
10 | Connector plug with connector "C4Z" (AMP Junior Timer) (order separately, see "Accessories") |
11 | Connector plug with "K4" connector (order separately, see "Accessories") |
16 | Nameplate |
17 | Oil ports A, B, P, TA, and TB have the same sealing ring |
18 | Protective plug for valve with a coil on side B |
19 | Protective plug for valve with a coil on side A |
20 | Space required to remove the connector plug/right-angle socket |
21 | Space required to remove the coil |
22 | Installing nut, tightening torque MA=14.5±1.5Nm |
23 | Oil port mounting surface conforms to ISO4401-05-04-0-05 |
24 | When connecting to additionally machined holes, only connector TB can be used. |
DC Voltage - Centering Connection Dimensions in mm |
Required Surface Quality for Valve Contact Surface |
6 | Cover |
12 | Cable Bundle Coils "DL" and "DAL" |
13 | Central Connection Components "DK6L" and "DK25L" |
14 | Connecting Plug for Valves with Center Connection and Connector "DK6L" (Order separately, see "Accessories") |
15 | Small Exchange Connector "DK25L", 5-Pole (Order separately, Part No. R900057631) |
20 | Space required to remove the connector plug/right-angle socket |
22 | Installing nut, tightening torque MA=14.5±1.5Nm |
23 | Oil port mounting surface conforms to ISO4401-05-04-0-05 |
24 | When connecting to additionally machined holes, only connector TB can be used. |
DC Voltage - Manual Emergency Operation Dimensions in mm |
Required Surface Quality for Valve Contact Surface |
3 | Without and with Implicit Manual Emergency Operation "N9" (Standard) |
4 | With hidden manual emergency operation and protective cap "N8". (The protective cap must be removed before operation.) |
5 | Manual emergency operation "Mushroom Button" "N5" and "N6" can be locked |
AC voltage - single connection Dimensions in mm |
Required surface quality for valve contact surface |
1 | Coil “a” |
2 | Coil “b” |
3 | Without and with Implicit Manual Emergency Operation “N9” (Standard) |
7 | Connector plugs without connector “K4” and “K4K” lines (order separately, see “Accessories”) |
11 | With connector “K4” Connection plug for the line (order separately, see "Accessories") |
16 | Nameplate |
17 | Oil ports A, B, P, TA and TB have the same sealing ring |
18 | Protective plug for valve with a coil on side B |
19 | Protective plug for valve with a coil on side A |
20 | Space required to remove the connector plug/right-angle socket |
21 | Space required to remove the coil |
23 | Oil port mounting surface conforms to ISO4401-05-04-0-05 |
24 | When connecting to additionally machined holes, only connector TB can be used. |
AC Voltage - Centering ConnectionDimensions in mm |
Required Surface Quality for Valve Contact Surface |
3 | Without and with Implicit Manual Emergency Operation "N9" (Standard) |
6 | Cover |
12 | Cable Bundle Coils "DL" and "DAL" |
13 | Central Connection Components "DK6L" and "DK25L" |
14 | Connecting Plug for Valves with Center Connection and Connector "DK6L" (Order separately, see "Accessories") |
15 | Small Exchange Connector "DK25L", 5-Pole (Order separately, Part No. R900057631) |
20 | Space required to remove the connector plug/right-angle socket |
21 | Space required to remove the coil |
22 | Installing nut, tightening torque MA=14.5±1.5Nm |
23 | Oil port mounting surface conforms to ISO4401-05-04-0-05 |
24 | When connecting to additionally machined holes, only connecting... | TB.
Technical Specifications
| Specification | Value |
|---|---|
| Brand | Bosch Rexroth |
| Series | WE |
| Category | Directional Control Valve |
Plain language sourcing guide for Rexroth directional control valve, R901278744=4WE10J5X/EG24N9K4/M
Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.
Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.
Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.
If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.
Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.
Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.
Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.
Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.
For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.
For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.
For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.
| Brand Name: | Rexroth | Certification: | ISO9001, CE |
|---|---|---|---|
| Place of Origin: | China | Condition: | New |
| Warranty: | 1 year | Customized sourcing: | available |
What are your strengths?
Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.
What is your estimated delivery time?
Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.
What are your primary product offerings?
Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.
How can I get in touch with you?
Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.
What are your payment terms?
Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.
Feel free to Ask questions
Rexroth directional control valve, R901278744=4WE10J5X/EG24N9K4/M
Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.
For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.
Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.
Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.
- Confirm the complete model number and any suffix printed on the nameplate.
- Share quantity, destination country, preferred shipping method, and target delivery date.
- Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
- Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.
Useful details for a faster quote
- Complete model and part number
- Required quantity and target delivery date
- Nameplate photos, drawings, or old purchase records
- Voltage, signal range, dimensions, or accessory needs
Model matching
We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.
Quality and delivery
Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.
Stock alternatives
For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.
Rexroth directional control valve, R901278744=4WE10J5X/EG24N9K4/M verification notes
Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.
LEHIY reviews product name, part number, series, label information, and application requirements before shipment.
If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.
For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.
Related Products
Explore More
More In This Category
Trusted partners
We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.