

Burkert MFC Gas Mass Flow Controller Model 8746
LEHIY item code: LH-0369
Quick buying check
This page helps you check Burkert MFC Gas Mass Flow Controller Model 8746 before you ask for a quote.
Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.
LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.
Burkert MFC and 8742 Mass Flow Controllers: Gas Mass Flow Controllers and Mass Flow Meters with Analog or Profibus-DP Interfaces. Our Burkert MFC and MFM mass flow controllers (models 8742 and 8746) are now available in both analog and Profibus-DP communication versions. Learn more about the advantages.
In addition to the existing büS/CANopen versions, the Burkert MFC and MFM mass flow controllers (models 8742 and 8746) are now available with standard analog signal interfaces or Profibus-DP communication versions. This gives you more options and flexibility in your system design.
Direct Measurement in the Gas Flow: The sensors of the Burkert MFC and MFM gas mass flow controllers are located directly in the gas flow and calibrated with real gas. This gives them high dynamic characteristics and measurement accuracy, as well as ultra-fast response and settling time.
Thanks to their IP65 and IP67 protection ratings, the robust field-ready units 8742 and 8746 can be used directly in the field without needing to be housed in a control cabinet. Furthermore, ATEX/IECEx Zone 2 Category 3 G/D certified versions are also available.
Advantages of the Burkert Gas Mass Flow Controllers (MFC) Models 8742 and 8746: ✓ Highest actual measurement accuracy in its class thanks to sensors calibrated directly in the gas flow. ✓ IP65 and IP67 protection ratings, suitable for harsh environments.
✓ Low maintenance costs due to stable flow calibration over long periods and the absence of moving parts in the medium.
✓ Easy integration into existing systems.
Learn more about Burkert Gas Mass Flow Controllers with Profibus-DP MFC and MFM: Burkert Gas Mass Flow Controller Model 8742 Burkert Gas Mass Flow Controller Model 8746 Burkert Gas Mass Flow Controller Learn more about Burkert Gas Mass Flow Controllers with Analog Interfaces MFC and MFM: Burkert Gas Mass.
Flow Meter Model 8742 8746 Burkert Gas Mass Flow Meter/Burkert Gas Mass Flow Controller Structure and Operating Principle What is the Burkert Gas Mass Flow Controller (MFC)?
Burkert's Mass Flow Controller (MFC) and Mass Flow Meter (MFM) are different devices. The MFC controls the mass flow rate of a gas, while the MFM does not.
The Burkert Mass Flow Controller (MFC) is used for precise measurement and control of gas mass flow rate; implantation, vacuum coating equipment, fiber optic melting, microreactors, gas mixing systems, capillary gas chromatographs, and fiber optic manufacturing equipment.
Burkert gas flow meters and mass flow controllers are widely used in petrochemical, metallurgical, and pharmaceutical industries. Features: high accuracy and good repeatability.
- Burkert Gas Mass Flow Controller Structure: The Burkert Gas Mass Flow Controller (MFM) consists of a circuit board, sensor, inlet and outlet gas pipe connectors, splitter channel, and housing. It can only measure gas mass flow rate. Adding a regulating valve to the MFM creates the MFC, which can both measure and control gas mass flow rate.
- Burkert Gas Mass Flow Meter/Burkert Gas Mass Flow Controller Working Principle: After the airflow enters the inlet pipe, most of the flow passes through the splitter channel, with a small portion entering the capillary tube inside the Burkert sensor. Due to the special structure of the splitter channel, these two gas flow rates are directly proportional. The sensor is preheated, with its internal temperature higher than the incoming airflow temperature. The mass flow rate of this small portion of gas is measured using capillary heat transfer and differential calorimetry. The gas flow rate measured in this way can ignore the influence of temperature and pressure. The flow detection signal measured by the Burkert sensor is input to the circuit board, amplified, and then output, thus completing the function of the MFM. detection signal measured by the Burkert sensor is compared with the set signal given by the user. Based on this comparison, the regulating valve is controlled so that the flow detection signal is equal to the set signal. This achieves the function of the Burkert gas mass flow controller MFC.
Plain language sourcing guide for Burkert MFC Gas Mass Flow Controller Model 8746
Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.
Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.
Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.
If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.
Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.
Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.
Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.
Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.
For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.
For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.
For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.
| Brand Name: | Burkert | Certification: | ISO9001, CE |
|---|---|---|---|
| Place of Origin: | China | Condition: | New |
| Warranty: | 1 year | Customized sourcing: | available |
What are your strengths?
Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.
What is your estimated delivery time?
Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.
What are your primary product offerings?
Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.
How can I get in touch with you?
Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.
What are your payment terms?
Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.
Feel free to Ask questions
Burkert MFC Gas Mass Flow Controller Model 8746
Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.
For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.
Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.
Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.
- Confirm the complete model number and any suffix printed on the nameplate.
- Share quantity, destination country, preferred shipping method, and target delivery date.
- Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
- Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.
Useful details for a faster quote
- Complete model and part number
- Required quantity and target delivery date
- Nameplate photos, drawings, or old purchase records
- Voltage, signal range, dimensions, or accessory needs
Model matching
We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.
Quality and delivery
Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.
Stock alternatives
For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.
Burkert MFC Gas Mass Flow Controller Model 8746 verification notes
Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.
LEHIY reviews product name, part number, series, label information, and application requirements before shipment.
If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.
For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.
Related Products
Explore More
More In This Category
Trusted partners
We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.










