Burkert flow switch, Burkert 8025 flow meter
LEHIY item code: LH-0365
Quick buying check
This page helps you check Burkert flow switch, Burkert 8025 flow meter before you ask for a quote.
Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.
LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.
Burkert flow switch Burkert 8025 flow meter 418778 418779 418762 Burkert insertion turbine flow meter or batch controller, Burkert flow meter 8025 model 418778 418779 418762 turbine flow transmitter for continuous flow measurement and batch control is specifically designed for neutral and slightly corrosive liquids that do not contain solids.
The performance aspects of Burkert flow meters mainly include: measuring flow (instantaneous flow) or total flow (cumulative flow); accuracy requirements; repeatability; linearity; flow range and rangeability; pressure loss; output signal characteristics and flow meter response time, etc.
- Measuring flow or total flow Burkert flow meter flow measurement includes two types, namely instantaneous flow and cumulative flow. For example, for crude oil in distribution station pipelines, which are trade transfers or for continuous proportioning production or process control of production processes, total flow needs to be measured, and instantaneous flow is occasionally observed. In some workplaces, instantaneous flow measurement is required for flow control. Therefore, the selection should be based on the needs of on-site measurement. Some Burkert flow meters, such as volumetric flow meters and turbine flow meters, measure the total volume directly by mechanical counting or pulse frequency output. They have high accuracy and are suitable for measuring total volume. If equipped with a corresponding signaling device, they can also output flow rate. Electromagnetic flow meters and ultrasonic flow meters derive flow rate by measuring fluid velocity. They have fast response and are suitable for process control. If equipped with an integration function, they can also obtain the total volume.
- Accuracy The accuracy class of Burkert flow meters is specified within a certain flow range. If used under specific conditions or within a relatively narrow flow range, such as only varying within a very small range, its measurement accuracy will be higher than the specified accuracy class. For example, if a turbine flow meter is used to measure oil for barrel distribution, and the valve is fully open, the flow rate is basically constant, and its accuracy may increase from 0.5 class to 0.25 class. Burkert flow switch, Burkert 8025 model flow meter, model 418762. High-resolution original photos of the product: Burkert 8025 flow switch, Burkert 8025 flow meter, models 418778, 418779, 418762. 418397, 418423, 418424, 418431, 418992, 418994, 419520, 419522418762G, 802500-BC89-PDFF-P1-A-F4-A-BCV/DC-A418763H, 802500-BC89-PDFF-P2-A-F4-A-BCV/DC-A418764A. 802500-BC89-PDFF-P3-A-F4-A-BCV/DC-A418765B 802500-BC89-PDFF-P4-A-F4-A-BCV/DC-A418778Q 802500-BC89-PDFF-P1-A-F4-C-BCV/DC-G418779R 802500-BC89-PDFF-P2-A-F4-C-BCV/DC-G418780F 802500-BC89-PDFF-P3-A-F4-C-BCV/DC-G418950H 822500-BC89-PDFF-C1-A-F1-A-BCV/DC-A418951W 822500-BC89-PDFF-C2-A-F1-A-BCV/DC-A418952X 822500-BC89-PDFF-C3-A-F1-A-BCV/DC-A418953Y 822500-BC89-PDFF-C4-A-F1-A-BCV/DC-A Burkert Flow Transmitter Installation Precautions:
- Burkert flow transmitters operate based on the principle of vibration, and in their operation, they utilize electromagnetic technology for vibration excitation, torsion detection, and signal processing. Therefore, the installation location of the Burkert flow transmitter should not be near large vibration sources, nor should it be installed near equipment that generates strong magnetic fields, such as transformers or motors, to prevent external interference from affecting its normal operation.
- The installation of the Burkert flow transmitter does not require a straight pipe section, but stress should be avoided when the sensor and the pipeline. If there is a deviation in the concentricity between the sensor and the pipeline centerline during the installation of the Burkert flow transmitter, stress will be generated in the vibrating tube. fluctuations, and affecting measurement accuracy [3, 4]. If the concentricity deviation between the pipeline and the sensor is too large, it may be impossible to adjust the zero point. Therefore, reinforcement measures should be taken to stabilize the pipeline near the instrument. A flexible connection should be used as much as possible when installing the flow sensor, and the flange connection bolts should be tightened evenly and symmetrically. To reduce the influence of residual stress, the flow sensor should be zero-point calibrated after installation. To facilitate the installation and zeroing of the Burkert flow transmitter, shut-off valves should be installed at the front and rear ends of the Burkert flow transmitter.
- The connecting cable between the sensor and the transmitter should use the manufacturer's cable;
- the transmitter receives low-level signals, so the cable should not be too long. When installing the transmitter, ensure the partition separating the intrinsically safe sensor cable from the power and output cables is properly in place;
- ensure the sensor junction box and transmitter housing are sealed to prevent short circuits that could lead to measurement errors or flow meter malfunctions.
- Select different sensor installation orientations based on the fluid properties. Always keep the fluid in the sensor flow tube full. For gas feed measurement, the U-tube of the Burkert flow transmitter should face upwards to prevent condensation buildup in the measuring tube; for the LUX type, adjust the potentiometer located next to the display module;
- for the LUY type, adjust the potentiometer in the temperature and pressure circuit on the lower left of the main board (only one). Rotating the potentiometer clockwise decreases the displayed pressure value. The Burkert flow transmitter can measure the flow rate of dirty media, corrosive media, and suspended liquid-solid two-phase flows. Since the only flow components inside the measuring tube of the instrument are the lining and electrodes, which come into contact with the fluid being measured, their materials can be selected based on the properties of the fluid. For example, using polytetrafluoroethylene (PTFE) or polytetrafluoroethylene (PTFE) as the lining allows for the measurement of various corrosive media such as acids, alkalis, and salts;
- using wear-resistant rubber as the lining is particularly suitable for measuring liquid-solid two-phase flows such as slurries and cement slurries containing solid particles and exhibiting significant abrasion, as well as various fibrous liquids and suspensions such as pulp. Features of Burkert flow transmitters and Burkert flow switches: ① The internal circuitry of Burkert flow transmitters uses surface mount technology, resulting in a compact structure and high reliability. ② Burkert flow transmitters can operate with either internal or external power supplies depending on site requirements, resulting in low overall power consumption. ③ Burkert flow transmitters have a password setting function.
Plain language sourcing guide for Burkert flow switch, Burkert 8025 flow meter
Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.
Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.
Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.
If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.
Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.
Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.
Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.
Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.
For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.
For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.
For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.
| Brand Name: | Burkert | Certification: | ISO9001, CE |
|---|---|---|---|
| Place of Origin: | China | Condition: | New |
| Warranty: | 1 year | Customized sourcing: | available |
What are your strengths?
Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.
What is your estimated delivery time?
Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.
What are your primary product offerings?
Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.
How can I get in touch with you?
Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.
What are your payment terms?
Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.
Feel free to Ask questions
Burkert flow switch, Burkert 8025 flow meter
Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.
For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.
Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.
Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.
- Confirm the complete model number and any suffix printed on the nameplate.
- Share quantity, destination country, preferred shipping method, and target delivery date.
- Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
- Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.
Useful details for a faster quote
- Complete model and part number
- Required quantity and target delivery date
- Nameplate photos, drawings, or old purchase records
- Voltage, signal range, dimensions, or accessory needs
Model matching
We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.
Quality and delivery
Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.
Stock alternatives
For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.
Burkert flow switch, Burkert 8025 flow meter verification notes
Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.
LEHIY reviews product name, part number, series, label information, and application requirements before shipment.
If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.
For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.
Related Products
Explore More
More In This Category
Trusted partners
We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.