../../images-webp/LH-BURKERT-0309-1.webp

Burkert pH electrode model 8203 (00418319)

LEHIY item code: LH-0304

We are an authorized distributor of Burkert pH electrode model 8203 (00418319), Ceratrode pH 1200 ID.Nr..418319. pH: 0.. 14, T: 0...130°C, p: 0... 16 bar. LEHIY Industrial is an authorized distributor of German Burkert pH/REDOX electrode type 8203 / product number 418319. Technical attributes: Analysis | 0.00 °C - 130.00 °C | Glass

Quick buying check

This page helps you check Burkert pH electrode model 8203 (00418319) before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

We are an authorized distributor of Burkert pH electrodes, model 8203

  • , Ceratrode pH 1200 ID.Nr..418319. pH: 0.. 14, T: 0...130°C, p: 0... 16 bar. LEHIY Industrial is an authorized distributor of German Burkert pH/REDOX electrodes, type 8203 / product number 418319. Technical attributes: Analysis | 0.00 °C - 130.00 °C | Glass type 8203 - Burkert pH electrodes and Burkert O.RP probes. Description: Burkert pH or redox potential meters are modular measuring devices used to measure: - the pH in clean, contaminated liquids or liquids containing small amounts of solids, sulfides, or proteins. - redox potential: - in clean, contaminated liquids or liquids containing small amounts of solids, sulfides, or proteins, which have low conductivity. The Burkert 8203 probe is available in several different versions: For pH measurement: - PLASTRODE pH 120 mm - FLATRODE pH 120 mm - LOGOTRODE pH 120 mm - UNITRODE PLUS pH 120 mm - CERATRODE pH 120 mm - FERMTRODE VP pH 120 mm;
  • For ORP: - FLATRODE ORP 120 mm - LOGOTRODE ORP 120 mm - UNITRODE PLUS ORP 120 mm. Features of the Burkert 8203 probe: Suitable for many different types of installations and applications. Multiple Burkert probes are available with various supports suitable for DN15 - DN200 pipes. The 8203 pH electrode is compatible with the following products: Type 8200 (accessories for Burkert analytical probes);
  • Type 8202 (pH or redox Burkert potentiometric transmitters, ELEMENT...);
  • Type 8619 multiCELL... Burkert multifunction transmitter. The working principle of the Burkert pH electrode: The Burkert pH/ORP electrode, also known as a pH/ORP sensor or pH/ORP probe, is used with a pH/ORP transmitter to form a pH/ORP measurement system. The effectiveness of a Burkert pH meter largely depends on electrode maintenance. The electrode should be frequently cleaned to ensure it is not contaminated;
  • The electrode should be calibrated periodically;
  • During water outages, the electrode should be immersed in the solution being measured, otherwise its lifespan will be shortened;
  • The cable connector must be kept clean and protected from moisture or water ingress. Burkert pH electrode installation precautions:
  • The electrode cable connector must be kept clean and protected from moisture or water ingress, otherwise the measurement value will be significantly inaccurate, and the instrument may not even function properly.
  • The electrodes should be cleaned frequently to ensure they are not contaminated.
  • The electrodes should be recalibrated periodically, with the specific interval depending on the local medium.
  • During non-operational periods, if the electrode membrane cannot be immersed in the measured solution or water, the electrode should be removed and immersed in a 1 mol KCl solution. Do not allow the electrode membrane to dry out, as this will shorten its lifespan.
  • Before using the electrode, if the electrode membrane is dry, it should be soaked in a 3 mol KCl solution for a period of time, generally at least 24 hours.
  • The electrode membrane is a very thin layer of special glass. Exercise extreme care during installation, calibration, and cleaning to avoid damaging the membrane.
  • Do not install the sensor cable in the same terminal as the AC or DC power cord. Excessively long cables should not be coiled and placed near motors or other equipment, as this may generate electromagnetic fields. During installation, trim excess cable to ensure an appropriate length, thus avoiding unwanted induced signals (“electrical noise” may interfere with the sensor signal). commonly used), 560377, 560378, 560379, 561025, 561027, 552041, 418319.

Plain language sourcing guide for Burkert pH electrode model 8203 (00418319)

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:BurkertCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

Burkert pH electrode model 8203 (00418319)

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

Burkert pH electrode model 8203 (00418319) verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo
fusheng logo