../../images-webp/LH-BURKERT-0298-1.webp
../../images-webp/LH-BURKERT-0298-2.webp
../../images-webp/LH-BURKERT-0298-3.webp
../../images-webp/LH-BURKERT-0298-1.webp
../../images-webp/LH-BURKERT-0298-2.webp
../../images-webp/LH-BURKERT-0298-3.webp

Burkert flow meter distributor, model 8025T transmitter 418762

LEHIY item code: LH-0293

We are an authorized distributor of Burkert 8025T transmitters (models 418762 and 418778). Special discounts are available for this project. Fast delivery, French manufacturing, genuine product with a 1-year quality guarantee. Delivery includes the Burkert 8025 transmitter's factory test report. After-sales installation guidance and other services are provided. The German Burkert 8025 flow meter, also known as the Burkert flow transmitter 418762 (model 8025-BC89-PDFF-P1-A-F4-A-BDN/DC-A), is available in limited quantities for project use.

Quick buying check

This page helps you check Burkert flow meter distributor, model 8025T transmitter 418762 before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

Burkert 8025T flow meter transmitter (model 418762, 418778) is available through a special project-approved discount. Fast delivery, French origin, genuine quality guaranteed for one year, and includes the Burkert 8025 model's factory test report. After-sales installation guidance and other services are also provided.

The German Burkert 8025 flow meter, also known as the Burkert flow transmitter (model 418762, 8025-BC89-PDFF-P1-A-F4-A-BDN/DC-A), is available in limited quantities and is subject to periodic restocking.

Burkert 8025T Transmitter Classification: Burkert panel-mounted or wall-mounted transmitters and the 8025T split-type Burkert transmitter.

8025T Panel-Mounted Transmitter Introduction: The 8025T panel-mounted flow transmitter is an 8025T electronic module integrated into the front panel housing. It is compatible with the 8020 model (see pages 400-401), the 8030 "low power" model (see pages 376-377), or other Burkert flow sensors.

General-purpose transmitters can also be used with commercially available standard flow sensors. Burkert 8025T Wall-Mounted Flow Transmitter Introduction: The 8025T wall-mounted Burkert flow transmitter is an 8025T electronic module integrated into an IP 65 housing.

Compatible with this type are the 8020 model (see pages 400-401), the 8030 "low power" model (see pages 376-377), or other Burkert flow sensors. The general-purpose transmitter can also be used with commercially available standard flow sensors.

Burkert 8025T Transmitter Product Introduction: The 8025T Burkert insertion flow transmitter is specifically designed for neutral, slightly corrosive liquids free of solid particles. The integrated Burkert transmitter includes an electronic module and a Burkert turbine sensor.

As liquid flows through the pipe, the turbine begins to rotate and generates a frequency signal proportional to the flow rate in the transmitter (coil type for battery power, Hall type for others). The electronic module within the German Burkert transmitter converts this frequency signal into various output signals.

The Burkert insertion fitting system allows for easy installation of the sensor in all pipes from DN15 to DN400.

The Burkert 8025 T-type flow transmitter is available in the following forms: ● Burkert universal integrated transmitter ● Burkert split transmitter (panel-mount or wall-mount), compatible with commercially available standard flow sensors ● Burkert split transmitter (panel-mount or wall-mount) wall-mount), compatible with Burkert 8020/8030 sensors.

The 8025T Burkert flow transmitter provides a standard signal or pulse output signal proportional to the flow rate. In addition, this transmitter features a flow display, two accumulators (total accumulator and daily accumulator), and two programmable relay outputs. Battery-powered models can display instantaneous and cumulative flow rates.

A convenient multilingual operating menu includes special functions such as Teach-in (for K-coefficient calibration) and flow simulation (for dry-state testing systems).

Ordering List for Burkert 8025T Transmitter: When ordering a complete Burkert 8025T transmitter set, please note: A complete 8025T transmitter set includes the 8025T transmitter and the S020 insert connector (pages 418-425).

The standard supply includes an FKM seal; the standard supply also includes one black EPDM sensor seal, one M20 x 1.5 cable connector plug, one 2 x 6mm multi-purpose seal, and one installation instruction manual. Please order the appropriate Burkert transmitter and Burkert S020 insert connector separately!

Please note! Burkert assumes no responsibility for incorrect selection.

Please contact your local Burkert branch office as early as possible during the design phase. Burkert Flow Meter Agent 8025T Transmitter 418762 418778 Project Special Discount, Additional Discount Available. Product Photos: Burkert Flow Meter Agent 8025T Transmitter Hot Selling Models: Burkert 8025 Insertion Flow Transmitter Order No.

00418762 Burkert 8025 Insertion Flow Transmitter Order No.

00418763 Burkert 8025 Insertion Flow Meter 418779 Burkert Flow Meter 8025HALLSHORT 3-Wire System 418778 Flow 8025 HALL SHORT; Panel Transmitter Order No.: 418992 (Two-wire, 12-30VDC, Output 4-20mA) 8025/S020 DN100 Welding Head, S020 Stainless Steel Welding Head, DN100, Order No.: 418114 8025/S020 DN125 Welding Head,.

S020 Stainless Steel Welding Head, DN125, Order No.: 418115 8025/S020 DN300 Welding Head, S020 Stainless Steel Welding Head, DN300, Order No.: 420070 The German Burkert 8025 flow transmitter 00418762 is currently in stock.

LEHIY Industrial is an authorized distributor of the entire Burkert flow meter series. Burkert insertion flow transmitter models in stock include: 418778, 418779, 418762, and 418763. 418431, etc.

Plain language sourcing guide for Burkert flow meter distributor, model 8025T transmitter 418762

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:BurkertCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

Burkert flow meter distributor, model 8025T transmitter 418762

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

Burkert flow meter distributor, model 8025T transmitter 418762 verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo
fusheng logo