Burkert Flow Meter Flow Switch 8012 Model 556001

LEHIY item code: LH-0283

Burkert Flow Meter 8012 Flow Switch Model 556001. The Burkert Flow Meter, Model 8012, order number 556001, is an electromagnetic turbine flow meter designed for neutral, slightly corrosive solids containing small amounts of liquid. A version is also available for IR transparent liquids in optical measurements. The Model 8012 consists of the S012 base connector and the SE12 electronic module.

Quick buying check

This page helps you check Burkert Flow Meter Flow Switch 8012 Model 556001 before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

Burkert Flow Meter 8012 Flow Switch Model. 556001. This Burkert electromagnetic turbine flow meter is designed for neutral, slightly corrosive solids containing small amounts of liquid. A version is also available for IR transparent liquids in optical measurements.

The 8012 model consists of the S012 base connector and the SE12 electronic module.

Burkert's assembly system simplifies installation for all DN06-DN65 fittings. It can also be integrated into custom valve systems.

With a fundamentally different electronic module type, the 8012 model features a pulse output that generates a flow proportional frequency or functions as an output switch, and also includes a 4…20 mA current output signal.

The main features of the Burkert 8012 flow switch are as follows: ---Low cost integration into piping systems, no additional piping required ---Optical or electromagnetic measurement principle---Outputs: 1 analog signal output 4...20mA and/or 1 transistor output (frequency or switch)---Settable output (via PC USB interface) The Burkert.

8012 turbine flow sensor is suitable for continuous flow measurement and is available in two forms: Optical Measurement: The 8012 optical type is specifically designed for liquids that allow infrared light to pass through.

Electromagnetic Measurement: The 8012 electromagnetic type is specifically designed for neutral, slightly corrosive, and solid-free liquids. The 8012 sensor consists of a connector (S012) and an electronic module (SE12), screwed together.

The sensor generates a programmable frequency pulse signal proportional to the flow rate, which can be easily transmitted and processed by the Burkert split transmitter/display (models 8025/8032). The sensor can also generate programmable digital output signals or 4-20 mA signals.

Burkert's connector system ensures easy installation in pipes ranging from DN 06 to DN.

  • It can also be installed in fluid combination control systems. The main parameters of the Baode 8012 flow switch are as follows: Measurement range: 0.5 - 1200 l/min;
  • Flow velocity: 0.3 - 10 m/s;
  • Accuracy: Standard K coefficient correction ≤ ±(0.5% of full scale * + 2.5% of reading);
  • Repeatability: ≤ ±0.4% of reading;
  • Electrical connection: Rotatable fixed connector M12, 5-pin power cable;
  • Maximum cross-section: 1.5 mm2;
  • Protection rating: IP67 with M12 cable plug;
  • Relative humidity: ≤ 80%, non-condensing;
  • Medium temperature: -15℃ to +100℃ (ambient temperature ≤ 45℃) or stainless steel or brass connector;
  • 15℃ to +90℃ (45℃ ≤ ambient temperature ≤ 60℃);
  • Ambient temperature: -15℃ to +60℃ (operating and storage);
  • Maximum medium pressure: PN16;
  • Medium viscosity/solid particle content: Maximum 300 cSt / Maximum 1% (particle size: 0.5 mm) Connector Material Brass, Stainless Steel Other Materials Electronic Module Housing/Cable Plug PPS/PA Turbine, Bracket PVDF Shaft and Bearing/Seal Ceramic (Al2O3)/FKM (Optional EPDM) Inner Hole DN 06 - DN 50 Operating Power Supply (V+) 12 - 36 V DC, filtered and rectified with reverse polarity and voltage peak protection Current Consumption < 60 mA (Current type 12 V DC, no load) Output Transistor Type Transistor NPN (default setting)/PNP (programmable on demand), open collector, maximum 700 mA NPN Output: 0.2 - 36V DC (default setting) PNP Output: Power Supply V+ Frequency or Switching Mode (programmable on demand) Current Type 4-20 mA, Sink Mode (default setting), Flow Rate Image (default setting), Programmable on demand (Source Mode);
  • Maximum Loop Impedance: 1125 Ω (36 V DC);
  • 650 Ω (24 V DC);
  • 140 Ω (12 V DC) Our company has a strong advantage in supplying Burkert flow meters and flow switches, model 8012
  • . The Burkert 556001 flow meter and flow switch is an 8012 type optical flow sensor, brass G1/2 inch, FKM sealed, 12~36VDC power supply. Several models of the Burkert 8012 flow meter and flow switch are available: 556003 556009 556010 556011 556012 556013 556014 556015 556016 556017 556020 556034 556045 556048 556049 556051 556052 556053 556054 For details regarding the Baode flow meter and flow switch model 8012
  • , please contact our sales department.

Plain language sourcing guide for Burkert Flow Meter Flow Switch 8012 Model 556001

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:BurkertCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

Burkert Flow Meter Flow Switch 8012 Model 556001

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

Burkert Flow Meter Flow Switch 8012 Model 556001 verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo
fusheng logo