../../images-webp/LH-BURKERT-0275-1.webp

Burkert pH electrode distributor, Burkert conductivity electrode 8221

LEHIY item code: LH-0270

Baode pH electrode distributor: Burkert conductivity electrode model 8221 (563054) is discontinued; replacement model 562420. Both the old and new Burkert conductivity electrodes are replacements; the mounting dimensions are 1 1/2 cm chuck. Please feel free to order the Burkert conductivity probe 562420 as a replacement. Burkert conductivity sensor model 8221 (563054COND 8221 PEEK SST CLAMP). German Baode Burkert conductivity electrode model 8221 (562420) parameters: 2852 chuck 1 1/2 cm.

Quick buying check

This page helps you check Burkert pH electrode distributor, Burkert conductivity electrode 8221 before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

Baode pH electrode distributor: Burkert conductivity electrode 8221 model 563054 is discontinued, replacement number 562420. Both the old and new Burkert conductivity electrodes are replacements, both with a 1 1/2 chuck mounting size. Please feel free to order the Burkert conductivity probe 562420 as a replacement.

Burkert conductivity sensor 8221 model 563054 COND 8221 PEEK SST CLAMP. German Baode Burkert conductivity electrode 8221 model 562420 parameters: 2852 1 1/2 chuck mounting, EPDM sealed, 4 electrodes + PTFE, K=0.147, with 3.1 certificate.

Burkert conductivity electrode 8221 model 563054 old model nameplate: Burkert conductivity electrode 8221 model description: 8221 sanitary conductivity probe is used to measure the conductivity of various pure or concentrated liquids.

Due to their hygienic and robust design, these conductivity probes are suitable for the food and pharmaceutical industries, as well as the biotechnology and chemical industries.

Features of the Burkert 8221 conductivity electrode: German Burkert conductivity sensor for hygienic applications . Ideal for demanding applications in the hygienic industry (CIP and SIP compatible) . Expanded range of conductivity measurements with multiple models . Support for most pipe interfaces to meet specific customer requirements .

Compatible with the Burkert 8619 multiCELL transmitter/controller.

Burkert conductivity probes are based on two different technologies: ● Probes based on the dual-electrode principle are suitable for measuring pure liquids, especially ultrapure water. Contamination can affect measurements. ● Probes based on the four-electrode principle prevent polarization effects and are insensitive to contamination.

This ensures excellent linearity throughout the measurement range. All versions integrate a Burkert temperature sensor (PT1000). The Burkert probe must be connected to the 8619 multiCELL transmitter/controller.

Burkert pH Electrode Selection and Ordering List for Model 8221 Conductivity Electrode: The Burkert 8221 conductivity electrode measurement principle: The conductivity of a solution is defined as its ability to conduct current. Charge carriers are ions (eg, dissolved salts or acids).

In a simple case, the measuring unit consists of two metal electrodes spaced a fixed distance apart and having a specific cross-sectional area. An AC voltage supplied by the 8619 transmitter/controller is applied to the electrodes.

The measured current is a direct function of the number of ions in the solution. Conductivity can be calculated using Ohm's law.

The Burkert four-electrode probe consists of two current electrodes and two voltage electrodes. An AC current flows between the two current electrodes and is regulated by the 8619 Burkert transmitter/controller.

The corresponding voltage is measured by the two voltage electrodes, and a voltage drop occurs in the solution being tested.

This voltage drop depends on the conductivity of the solution. Due to this measurement principle, the Burkert four-electrode probe has a significantly wider linear measurement range and is insensitive to contamination and polarization by using AC at an appropriate frequency.

Numerous Burkert conductivity probes are available on the market, with varying measurement ranges.

Installation of the Burkert 8221 Conductivity Electrode Product 6.1. Installation Tips for Burkert Four-Electrode Conductivity Probes with 1½" Chuck or G 1¼" Pipe Connections: • The Burkert conductivity electrode must be installed at a washable pipe connection. • The conductivity probe should be installed according to the following instructions.

Dual or quad electrode conductivity probes with chuck, G or NPT pipe fittings and M12 plugs: . Install the Burkert probe in a 1½" stainless steel hole sanitary T-fitting, or in a properly threaded, screwing the screw* into or into the pipe to the appropriate depth, as shown below. .

The diagram shows the installation with a chuck pipe fitting.

The same method can be used for G or NPT pipe fittings.

Plain language sourcing guide for Burkert pH electrode distributor, Burkert conductivity electrode 8221

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:BurkertCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

Burkert pH electrode distributor, Burkert conductivity electrode 8221

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

Burkert pH electrode distributor, Burkert conductivity electrode 8221 verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo
fusheng logo