Burkert 8202 PH ORP transmitter
LEHIY item code: LH-0268
Quick buying check
This page helps you check Burkert 8202 PH ORP transmitter before you ask for a quote.
Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.
LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.
The Burkert 8202 pH ORP transmitter is a compact measuring instrument used to measure pH or oxidation-reduction potential (ORP): ● pH value: in clean liquids, contaminated liquids, liquids containing sulfides or proteins. ● Oxidation-reduction potential: in clean liquids, contaminated liquids, liquids containing sulfides or proteins, and liquids exhibiting low conductivity.
Through its design, Burkert simplifies installation and maintenance.
The Burkert 8202 pH ORP transmitter is available in two specifications: ● The first, called the ELEMENT standard model, offers three adjustable outputs (two digital outputs and one analog output) or four outputs (two digital outputs and two analog outputs), and can also be equipped with a display screen.
A display screen is only required for commissioning, configuration (eg, selecting pH/ORP measurement, measurement range, unit, calibration, limits, etc.) or as a process value display.
● The second type, called the ELEMENT neutrino type, is a two-wire device without a display screen and with a 4…20 mA current output.
The Powertech pH ORP transmitter, model 8202, converts the measurement signal. For ELEMENT standard devices, it displays different measurement values in different units (if a display is installed) and calculates the output signal.
This signal is connected via one or two M12 connectors in the ELEMENT standard version, and via one M12 connector or a cable threaded sleeve connector on a terminal block in the ELEMENT neutrino device.
The Burkert pH ORP meter, model 8202, has the following main features: ---Integrated compact meter directly connected to the control layer (SPS control unit) ---Parameter data setting, calibration, and transmission via a detachable display module/configuration module ---Quick and easy conversion between pH and ORP measurements ---Uses a 120 mm.
standard PG 13.5 pH probe/oxidation-reduction potential probe with an S8 interface (model 8203 recommended) ---Simple one- or two-point calibration, simulation process values, and diagnostic functions can be performed directly on the device.
The Burkert pH ORP meter, model 8202, has the following main parameters: Pipe diameter DN15-200 (S020 type connector) Measurement range -2000 to +2000 mV Minimum measurement range 50 mV (corresponding to 4-20mA) Sensor Electrode: UNITRODE PLUS ORP Medium Minimum conductivity 2 μS/cm (200 kΩ·cm) for clean.
or contaminated media with low conductivity or containing sulfides/proteins.
Medium pressure/temperature 0-6 bar / 0-130 °C. Maximum pressure at maximum temperature 6 bar. Housing/diaphragm: Glass / 2 unclogging "single-hole" ports. Reference electrolyte: Polymer accuracy ±3 mV, electrical connection after proper electrode calibration. Cable plug DIN EN 175301-803 or cable connector M20X1.5.
Connecting cable: Shielded cable, maximum cross-section: 1.5 mm². Protection rating IP65, with plugs or connectors when connected or sealed when not in use. Relative humidity ≤ 80%, non-condensing. Medium temperature: PVC connector: 50℃; PP connector: 80℃; PVDF connector: 100℃; brass or stainless steel connector: 130℃.
Ambient temperature: Operating/storage.
0-60℃/4-30℃ (electrode limited) Maximum medium pressure PN6 Material: Housing, cover, nuts PC Front panel sheet/screws Polyester/stainless steel cable plug, cable connector PA Wetted component connector Brass, stainless steel, PVC, PP or PVDF Sensor bracket PVDF Sealing FKM (EPDM also available as standard) Output 4-20.
mA, programmable (3-wire with relay; 2-wire without relay), proportional to ORP Maximum loop impedance: 1000 Ω (30 V DC); 750 Ω (24 V DC); 250 Ω (15 V DC) Relays (optional) 2, programmable, 3A, 230 V AC We have a strong advantage in supplying Burkert 8202 PH ORP.
transmitters.
Several models of the 8202 are available: 559630 559631 For details regarding the Burkert PH ORP measuring instrument, specifically the 8202 model, please contact our sales department. (Contact numbers: 559632, 559633, 559634, 559636, 561685, 561686, 563518)
Plain language sourcing guide for Burkert 8202 PH ORP transmitter
Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.
Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.
Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.
If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.
Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.
Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.
Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.
Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.
For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.
For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.
For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.
| Brand Name: | Burkert | Certification: | ISO9001, CE |
|---|---|---|---|
| Place of Origin: | China | Condition: | New |
| Warranty: | 1 year | Customized sourcing: | available |
What are your strengths?
Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.
What is your estimated delivery time?
Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.
What are your primary product offerings?
Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.
How can I get in touch with you?
Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.
What are your payment terms?
Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.
Feel free to Ask questions
Burkert 8202 PH ORP transmitter
Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.
For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.
Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.
Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.
- Confirm the complete model number and any suffix printed on the nameplate.
- Share quantity, destination country, preferred shipping method, and target delivery date.
- Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
- Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.
Useful details for a faster quote
- Complete model and part number
- Required quantity and target delivery date
- Nameplate photos, drawings, or old purchase records
- Voltage, signal range, dimensions, or accessory needs
Model matching
We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.
Quality and delivery
Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.
Stock alternatives
For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.
Burkert 8202 PH ORP transmitter verification notes
Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.
LEHIY reviews product name, part number, series, label information, and application requirements before shipment.
If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.
For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.
Related Products
Explore More
More In This Category
Trusted partners