Burkert 93161500 , PowerEdge 8221 conductivity electrode.

LEHIY item code: LH-0187

Burkert 93161500 conductivity electrode for use in water injection systems (model 8221). This Burkert 93161500 conductivity electrode is a custom-designed product by Burkert for the biopharmaceutical industry, a specific product*, and a designated product for sanitary applications. Burkert probes have their irreplaceable special features. water injection systems: 8221 PEEK SST 1.5 Clamp k

Quick buying check

This page helps you check Burkert 93161500 , PowerEdge 8221 conductivity electrode. before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

The Burkert 93161500 conductivity electrode is available for use in water injection systems. This Burkert 93161500 conductivity electrode is a customized product of Burkert for the biopharmaceutical industry.

water injection systems: 8221 PEEK SST 1.5 Clamp k=0.01 8221-TM46-VAAA-C1-A-F1-S-000/00-0*/ Burkert conductivity probe model. 93161500. Burkert 8221 conductivity electrode K=0.01: Suitable for sanitary applications (compatible with CIP and SIP). In stock. Burkert 93161500 K=0.01.

Features of Burkert 8221 conductivity electrode: Typ8221, Port connection, Clamp 50.5 x 38.6 x 1.5 according to ISO 2852, Material: stainless steel, Seal material: EPDM.

Sensor cellular constant K=0.01; Measuring range freely; Programmable function; Sensor measurement; Design fitting for analytic electrode and temperature Voltage without frequency; Output signal standard; Special feature: Flange sleeve M12 5pl, screwed cont.; Insertion length 65 mm with certification 3.1 Asia-version.

Technical attributes: Ambient temperature (degrees Celsius) (maximum) 60 degrees Celsius; Burkert conductivity electrode 93161500 8221; PEEK SST 1.5; Clamp sensor k=0.01; Actual picture: Burkert 93161500 in stock; Burkert 8221 conductivity electrode working principle: The working principle of Burkert conductivity electrode: Conductivity is the ability of an object.

to conduct current.

The measurement principle of the conductivity meter is to place two parallel plates in the solution to be measured, apply a certain potential (usually a sine wave voltage) across the two ends of the plates, and then measure the current flowing between the plates.

According to Ohm's Law, conductivity (G) is the reciprocal of resistance (R) and is determined by the conductor itself. The basic unit of conductivity is the siemens (S), originally called the ohm.

Because the geometry of the conductivity cell affects the conductivity value, standard measurements use unit conductivity S/cm to compensate for differences caused by various electrode sizes. Unit conductivity (C) is simply the product of the measured conductivity (G) and the cell constant (L/A).

Here, L is the length of the liquid column between the two plates, and A is the area of the plates. The conductivity of water is related to the amount of inorganic acids, alkalis, and salts it contains.

When their concentrations are low, conductivity increases with increasing concentration; therefore, this indicator is often used to estimate the total concentration of ions or salt content in water. Different types of water have different conductivity.

The conductivity of fresh distilled water is 0.2-2 μS/cm, but after standing for a period of time, it increases to 2-4 μS/cm due to CO2 absorption; the conductivity of ultrapure water is less than 0.10 μS/cm; the conductivity of natural water is mostly.

between 50-500 μS/cm, and that of mineralized water can reach 500-1000 μS/cm; the conductivity of industrial wastewater containing acids, alkalis, and salts often exceeds 10,000 μS/cm; and the conductivity of seawater is approximately 30,000 μS/cm.

The Burkert electrode constant is usually determined using a standard methyl chloride solution with known conductivity. The conductivity of methyl chloride solutions of different concentrations (25℃) is listed in the table below.

The conductivity of a solution is related to its temperature, polarization on the Burkert electrode, and electrode distributed capacitance, etc., and compensation or elimination measures are generally adopted in the instrument. Water samples should be measured as soon as possible after collection.

If coarse suspended matter, oil, and grease are present, interfering with the measurement, they should be removed by filtration or extraction.

Plain language sourcing guide for Burkert 93161500 , PowerEdge 8221 conductivity electrode.

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:BurkertCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

Burkert 93161500 , PowerEdge 8221 conductivity electrode.

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

Burkert 93161500 , PowerEdge 8221 conductivity electrode. verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo