Burkert Electrode Agent, Burkert Conductivity Electrode Model 8221

LEHIY item code: LH-0150

The Burkert conductivity electrode 8221 model (564898) is discontinued; replacement number 568818 (K=0.01). The new and old models are functional replacements; some product dimensions differ. All Burkert conductivity electrodes 8221 integrate a Burkert temperature sensor (Pt1000). The highest temperature resistance of the entire Burkert 8221 series of conductivity sensors is currently 150°C. 8221 electrode is used with distilled water (pure steam). Burkert conductivity electrode 8221 model (56489)

Quick buying check

This page helps you check Burkert Electrode Agent, Burkert Conductivity Electrode Model 8221 before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

Burkert electrode distributor, Baode conductivity electrode model 8221 (564898) , is discontinued; replacement number 568818 (K=0.01). The new and old models are functional replacements; some product dimensions differ. All Burkert conductivity electrodes 8221 integrate a Burkert temperature sensor (Pt1000).

The highest temperature resistance of the entire Burkert 8221 series of conductivity sensors is currently 150°C. The Burkert electrode 8221 uses distilled water (pure steam) as the medium.

Burkert conductivity electrode 8221 model 564898 (old model) specifications: Burkert electrode probe length 140mm, Clamp 1 1/2", φ50, 5mm, 50mm, included cable length 3m, temperature resistance 0-120°C. The 8221 conductivity electrode, order number 564898, is discontinued; replacement number 568818.

New specifications: Medium temperature: -20°C to 150°C; 8221 Burkert probe length: 65mm; Clamp size: Clamp 1 1/2", φ50, 5mm; Cable interface: M12, 5-pin; 5-pin M12 connector also available.

(917116 agent) Burkert conductivity electrode 8221 model 564898 (old model) actual product image: Burkert conductivity electrode 8221 model 564898 discontinued; replacement number 568818.

Comparison of old and new model structural dimensions: Burkert electrode distributor, Baode conductivity electrode 8221 model 564898 discontinued, replacement number 568818. Description of Burkert 8221 model conductivity electrode: The Burkert 8221 model hygiene-grade conductivity probe is widely used for measuring the conductivity of pure or concentrated liquids.

Due to its hygiene-grade and durable design, the conductivity probe is suitable for various applications, including the food and beverage industry, pharmaceuticals, biotechnology, and chemical industries.

The conductivity probe is based on two different technologies: • The probe using a dual-electrode structure is suitable for measuring pure liquids, especially ultrapure water, where contamination can affect the measurement. • The probe using a four-electrode structure prevents polarization effects and is insensitive to contamination.

The ingenious design ensures excellent linearity throughout the measurement range. All versions integrate a Burkert temperature sensor (Pt1000). The probe must be connected to the 8619 multiCELL transmitter/controller. Burkert 8221 Conductivity Electrode Probe: Suitable for sanitary applications (CIP and SIP compatible).

Available in multiple versions for use across a wide conductivity range. Supports major process interfaces to ensure specific customer requirements are met. Compatible with Burkert 8619 Multifunction Transmitter/Controller.

Plain language sourcing guide for Burkert Electrode Agent, Burkert Conductivity Electrode Model 8221

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:BurkertCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

Burkert Electrode Agent, Burkert Conductivity Electrode Model 8221

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

Burkert Electrode Agent, Burkert Conductivity Electrode Model 8221 verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo
fusheng logo