NX Series NX1P2 CPU Unit

Product Name Program Capacity Variable Capacity Use real-axis upper limit Built-in Input/Output Total Points Model
Motion control axis * 1 Single-axis position control axis * 1 Enter points Output points
NX1P2 CPU Unit 1.5MB32kB (power-off hold)/ 2MB (power-off not hold)8 Axis4-axis4-axis40 points24:0016-point, NPN transistorNX1P2-1140DT
16-point, PNP transistor * 2NX1P2-1140DT1
6 Axis2 Axis4-axis16-point, NPN transistorNX1P2-1040DT
16-point, PNP transistor * 2NX1P2-1040DT1
4-axis0 Axis4-axis24:0014 points10 point, NPN transistorNX1P2-9024DT
10 points, PNP transistor * 2NX1P2-9024DT1
 

NX Unit

Up to 8 units can be installed on the NX1P2 CPU Unit.

Digital input unit

Digital output unit

Product Name Specifications Model Overseas Standard
Enter Points Relay type Maximum switching capability I/O refresh method ON/OFF response time
Relay output unit (PUSH-IN fastening terminal block, width 12mm/width 24mm)2 pointsN.O.Maximum switching capacity: AC250V/2A(cos φ = 1) AC250V/2A(cos φ = 0.4) DC24V/2A, 4A/cellFree Run Refresh MethodLess than 15ms/Less than 15msNX-OC2633UC1, N, L, CE, RCM, KC
N.O.+N. C.NX-OC2733UC1, N, CE, RCM, KC
8 pointsN.O.Maximum switching capacity: AC250V/2A(cos φ = 1) AC250V/2A(cos φ = 0.4) DC24V/2A, 8A/unitFree run refresh methodBelow 15ms/Below 15msNX-OC4633UC1, N, L, CE, EAC, RCM, KC
* When using the timestamp to specify the output mode, it is necessary to EtherCAT the coupler unit Ver. 1.1 version above, Sysmac Studio Ver. 1.07 the above version.

Digital input/output mixing unit

Product Name Specifications Model Overseas Standard
Points Internal I/O Common Line Handling Rated voltage I/O refresh method ON/OFF response time
DC input/transistor output unit (MIL connector, width 30mm)Output: 16 points Input: 16 pointsOutput: NPN Input: NPN/PNP GeneralOutput: DC12 ~ 24V Input: DC24VAuto-run refresh or input/output synchronous refresh switchOutput: below 0.1ms/below 0.8ms Input: below 20μs/below 400μsNX-MD6121-5UC1, N, L, CE, RCM, KC
Output: PNP Input: NPN/PNP GeneralOutput: DC24V Input: DC24VOutput: below 0.5ms/below 1.0ms Input: below 20μs/below 400μsNX-MD6256-5
DC input/transistor output unit (Fujitsu connector, width 30mm)Output: 16 points Input: 16 pointsOutput: NPN Input: NPN/PNP GeneralOutput: DC12 ~ 24V Input: DC24VAutomatic operation refresh or input/output synchronous refresh switchOutput: below 0.1ms/below 0.8ms Input: below 20μs/below 400μsNX-MD6121-6
 

Analog input unit

Product Name Specifications Model Overseas Standard
Enter points Input range Resolution Conversion value, decimal number (0~100%) Accuracy (25 ℃) Input method Conversion time Input impedance I/O refresh method
Voltage input type 2 points-10~ +10V1/8000-4000 ~4000± 0.2% (full scale)Single-ended250 μs/pointMore than 1MΩFree RunNX-AD2603UC1, N, L, CE, RCM, KC
DifferentialNX-AD2604
1/30000-15000 ~15000± 0.1% (full scale)Differential10 μs/dotFree running/input output synchronizationNX-AD2608
4:001/8000-4000 ~4000± 0.2% (full scale)Single-ended250 μs/pointFree RunNX-AD3603
DifferentialNX-AD3604
1/30000-15000 ~15000± 0.1% (full scale)Differential10 μs/dotFree running/input output synchronizationNX-AD3608
8 points1/8000-4000 ~4000± 0.2% (full scale)Single-ended250 μs/pointFree RunNX-AD4603
DifferentialNX-AD4604
1/30000-15000 ~15000± 0.1% (full scale)Differential10 μs/dotFree running/input output synchronizationNX-AD4608
Current Input Type 2 points4~ 20mA1/80000~8000± 0.2% (full scale)Single-ended250 μs/point250ΩFree RunNX-AD2203
DifferentialNX-AD2204
1/300000~30000± 0.1% (full scale)Differential10 μs/dotFree running/input output synchronizationNX-AD2208
4:001/80000~8000± 0.2% (full scale)Single-ended250 μs/pointFree RunNX-AD3203
DifferentialNX-AD3204
1/300000~30000± 0.1% (full scale)Differential10 μs/dotFree running/input output synchronizationNX-AD3208
8 points1/80000~8000± 0.2% (full scale)Single-ended250 μs/point85ΩFree RunNX-AD4203
DifferentialNX-AD4204
1/300000~30000± 0.1% (full scale)Differential10 μs/dotFree running/input output synchronizationNX-AD4208
 

Analog output unit

Product Name Specifications Model Overseas Standard
Output points Output range Resolution Output set value, decimal number (0~100%) Accuracy (25 ℃) Conversion time I/O refresh method
Voltage output type 2 points-10~+10V1/8000-4000 ~4000± 0.3% (full scale)250 μs/dotFree RunNX-DA2603UC1, N, L, CE, RCM, KC
1/30000-15000 ~15000± 0.1% (full scale)10 μs/dotFree running/input output synchronizationNX-DA2605
4:001/8000-4000 ~4000± 0.3% (full scale)250 μs/dotFree RunNX-DA3603
1/30000-15000 ~15000± 0.1% (full scale)10 μs/dotFree running/input output synchronizationNX-DA3605
Current Output Type 2 points4~20mA1/80000~8000± 0.3% (full scale)250 μs/dotFree RunNX-DA2203
1/300000~30000± 0.1% (full scale)10 μs/dotFree running/input output synchronizationNX-DA2205
4:001/80000~8000± 0.3% (full scale)250 μs/dotFree RunNX-DA3203
1/300000~30000± 0.1% (full scale)10 μs/dotFree running/input output synchronizationNX-DA3205
 

Temperature input unit

Product Name Specifications Model Overseas Standard
Output points Input type Resolution Standard accuracy (ambient temperature 25 ℃) Conversion time I/O refresh method Terminal block
Thermocouple Input Type 2 pointsThermocoupleBelow 0.1°C * 1Please refer to our website (www.fa.omron.com .cn/) for product information.250ms/unitFree Run Refresh Method16 terminalsNX-TS2101UC1, N, L, CE, RCM, KC
4 points16 terminals × 2NX-TS3101
2 pointsBelow 0.01°C10ms/unit16 terminalsNX-TS2102
4 points16 terminals × 2NX-TS3102
2 pointsBelow 0.001°C60ms/unit16 terminalsNX-TS2104
4 points16 terminals × 2NX-TS3104
Temperature Measuring Resistor Type 2 pointsTemperature measuring resistor (Pt100/ Pt1000, 3-wire type) * 2Below 0.1°C * 1250ms/unit16 terminalsNX-TS2201
4 points16 terminals × 2NX-TS3201
2 pointsBelow 0.01°C10ms/unit16 terminalsNX-TS2202
4 points16 terminals × 2NX-TS3202
2 pointsBelow 0.001°C60ms/unit16 terminalsNX-TS2204
4 points16 terminals × 2NX-TS3204
* 1. When the input category is R, S, W, below 0.2 ℃. * 2. NX-TS2202 and NX-TS3202 are only applicable to Pt100 3-wire type.

Heater disconnection detection unit

Product Name Specifications Model Overseas Standard
CT Input Control Output
Points Maximum heater current Points Internal I/O Common Line Handling Maximum load current Rated voltage I/O refresh method
Thermocouple Input Type 4:00AC 50A4:00NPN0.1A/Point 0.4A/CellDC12~24VFree Run Refresh MethodNX-HB3101UC1, N, L, CE, RCM, KC
PNPDC24VNX-HB3201
 

Load sensor input unit

Product Name Specifications Model Overseas Standard
Points Transition period I/O refresh method * Load sensor applied voltage Input range
Load sensor input unit 1 point125μs· Free running refresh mode · Input/output synchronous refresh mode · Task cycle priority refresh modeDC5V±10%-5.0~+5.0mV/VNX-RS1201UC1, N, L, CE, RCM, KC
* For the communication cycle, please refer to "I/O Refresh Method" in the "NX Series Load Sensor Input Unit User Manual (SBCA-CN5-439)".

Position interface incremental encoder input unit

Product Name Specifications Model Overseas Standard
Number of channels External input number Maximum response frequency I/O refresh method Number of I/O entry mappings
Incremental Encoder Input Unit 1(NPN)3(NPN)500kHzAuto-run refresh mode, input/output synchronous refresh mode1/1NX-EC0112UC1, N, CE, RCM, KC
1(PNP)3(PNP)NX-EC0122UC1, N, L, CE, RCM, KC
13(NPN)4MHzNX-EC0132UC1, N, CE, RCM, KC
3(PNP)NX-EC0142UC1, N, L, CE, RCM, KC
2(NPN)None500kHz2/2NX-EC0212UC1, N, CE, RCM, KC
2(PNP)NX-EC0222UC1, N, L, CE, RCM, KC
 

Position Interface SSI Input Unit

Product Name Specifications Model Overseas Standard
Number of SSI channels Input/output specifications Maximum data length Encoder power supply Terminal block
SSI input unit 1RS-422 line driver/receiver32-bitDC24V, 0.3A/CHPush-in typeNX-ECS112UC1, N, L, CE, RCM, KC
2RS-422 line driver/receiver32-bitDC24V, 0.3A/CHPush-in typeNX-ECS212
 

Position interface pulse output unit

Product Name Specifications Model Overseas Standard
Number of channels * 1 External input number Number of external outputs Pulse output maximum speed I/O refresh method Number of I/O entry mappings Control output interface
Pulse Output Unit 1(NPN)2(NPN)1(NPN)500kppsInput/output synchronization refresh mode, task cycle priority refresh mode * 21/1Open collector outputNX-PG0112UC1, N, CE, RCM, KC
1(PNP)2(PNP)1(PNP)NX-PG0122UC1, N, L, CE, RCM, KC
25 points/CH (NPN)3 points/CH (NPN)4Mpps2/2Line Drive OutputNX-PG0232-5UC1, CE, RCM, KC
5 points/CH (PNP)3 points/CH (PNP)NX-PG0242-5
45 points/CH (NPN)3 points/CH (NPN)4/4NX-PG0332-5
5 points/CH (PNP)3 points/CH (PNP)NX-PG0342-5
* 1. Indicates the number of output channels of the pulse. * 2. Composable unit version Ver. 1.2 above is used in NX-ECC203 with EtherCAT coupler units.

Communication Interface Unit

Product name Serial Interface External connection terminal Serial port Communication function Model Overseas standards
Communication Interface Unit RS-232CNo screw fastening terminal1 port· No Protocol · Serial Line MonitorNX-CIF101UC1, N, L, CE, RCM, KC
RS-422A/485NX-CIF105
RS-232CD-Sub connector2 portsNX-CIF210
 

IO-Link master unit

Product Name Specifications Model Overseas Standard
Number of IO-Link ports I/O refresh method * Port connection terminal
I/O-Link Master Unit 4Free run refresh mode (fixed)Fastening terminals without screwsNX-ILM400UC1, N, L, CE, RCM, KC
 

System Unit

Product name Specifications Model Overseas standards
NX unit power supply additional supply unit Power supply voltage: DC24V(DC20.4 ~ 28.8V) NX unit power supply capacity: 10W or lessNX-PD1000UC1, N, L, CE, RCM, KC
I/O Power Supplements Unit Supply voltage: DC5 ~ 24V(DC4.5 ~ 28.8V) I/O supply maximum current: 4ANX-PF0630UC1, N, L, CE, RCM, KC
Supply voltage: DC5 ~ 24V(DC4.5 ~ 28.8V) I/O supply maximum current: 10A *NX-PF0730
I/O Power Connection Unit Number of IO power terminals: IOG:16 terminals I/O power terminal current capacity: 4A/terminals or lessNX-PC0010UC1, N, L, CE, RCM, KC
Number of IO power terminals: IOV:16 terminals I/O power terminals Current capacity: 4A/terminals or lessNX-PC0020UC1, N, L, CE, RCM, KC
Number of IO power terminals: IOV:8 terminals, IOG:8 terminals I/O power terminal current capacity: 4A/terminals or lessNX-PC0030UC1, N, L, CE, RCM, KC
Shielding connection unit Number of shield terminals: 14 terminals (2 terminals below are functional ground terminals)NX-TBX01UC1, N, L, CE, RCM, KC
* When using the NX-PF0730 on the CPU rack of the NX1P2 CPU unit, please use it below 4A.

The EtherCAT coupler

can be connected from the built-in EtherCAT port of the NX1P2 CPU unit to the EtherCAT coupler, using the aforementioned NX unit and NX series safety unit.  
Product name Communication cycle NX unit power consumption IO power supply maximum current Model Overseas standards
EtherCAT coupler unit * 1250~4000μs *2Below 1.45W4ANX-ECC201UC1, N, L, CE, KC
250~4000μs *210ANX-ECC202
125~10000μs *2Below 1.25WNX-ECC203
EtherCAT coupler unit comes with end cap NX-END01(1). * 2. Depends on EtherCAT master specifications. 500 μs, 1,000 μs, 2,000 μs, 4,000 μs for the NJ5 series connected to the built-in EtherCAT ports of the NJ/NX series CPU units. See the NJ/NX Series CPU Unit Built-in EtherCAT Port User's Manual (SBCD-CN5-358) for the latest specifications. depends on the unit composition.

Secure CPU Unit

Appearance Specifications Model Overseas Standard
Maximum Safe I/O Points Program capacity Security master connections I/O refresh method Unit version
256 point512KB32Free run refresh methodVer. 1.1NX-SL3300For more information, please refer to the product information on our website (www.fa.omron.com. cn/).
1024 point2048KB128Free run refresh methodVer. 1.1NX-SL3500
Note. The Security CPU Unit cannot be installed directly on the NX1P2 CPU Unit. Please connect to EtherCAT coupler for use.

Safety input unit

Appearance Specifications Model Overseas Standard
Security input points Test output points Internal I/O Common End Row Handling Rated input voltage Omron special safety input device Number of secure slave connections I/O refresh method Unit version
4 points2 pointsLeaky Input (PNP)DC24VConnectable1Free run refresh methodVer. 1.1NX-SIH400For more information, please refer to the product information on our website (www.fa.omron.com. cn/).
8 points2 pointsLeaky Input (PNP)DC24VNo connection1Free run refresh methodVer. 1.0NX-SID800
Note. The safety input unit cannot be installed directly on the NX1P2 CPU unit. Please connect to EtherCAT coupler for use.

Safety output unit

Appearance Specifications Model Overseas Standard
Security input points Internal I/O Common End Row Handling Maximum load current Rated input voltage Number of secure slave connections I/O refresh method Unit version
2 points

Plain language sourcing guide for Omron NX1P2 Mechanical Automation Controller

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:OmronCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

Omron NX1P2 Mechanical Automation Controller

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

Omron NX1P2 Mechanical Automation Controller verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo
fusheng logo