Mitsubishi Electric ELECTRIC inverter, FR-F840-02600-2-60
LEHIY item code: LH-0788
Ambient Temperature: Ambient Temperature
Category: Mitsubishi Electric ELECTRIC inverter
Rated Voltage: 3-phase 380 - 500V
Quick buying check
This page helps you check Mitsubishi Electric ELECTRIC inverter, FR-F840-02600-2-60 before you ask for a quote.
Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.
LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.
Technical Specifications
Below 95%RH (non-condensing) (with circuit board coating (corresponding to IEC60721-3-33C2_/3S2)); Below 90%RH (non-condensing) (without circuit board coating)
Storage Temperature
-20℃~+65℃
Ambient Environment
Indoor (free from corrosive gases, flammable gases, oil mist, dust, etc.)
Altitude • Vibration
Control Characteristics | Control Methods | Soft-PWM Control/High Carrier Frequency PWM Control (Selectable V/F Control (Optimal Excitation Control, etc.), Advanced Flux Vector Control (Optimal Excitation Control, etc.), PM Motor Control) | |
Output Frequency Range | 0.2~590Hz (with an upper limit of 400Hz for Advanced Flux Vector Control and PM Motor Control.) | ||
Frequency Setting Resolution | Analog Input | 0.015Hz/60Hz (Terminals 2, 4: 0~10V/12bit) 0.03Hz/60Hz (Terminals 2, 4: 0~5V/11 bit, 0~20mA/approx. 11 bit, Terminal 1: 0~±10V/12bit) 0.06Hz/60Hz (Terminal 1: 0~±5V/11 bit) | |
Digital Input | 0.01Hz | ||
Frequency Accuracy | Analog Input | Maximum output frequency within ±0.2% (25℃±10℃) | |
Digital input | Set output frequency within 0.01% | ||
Voltage/frequency characteristics | The reference frequency can be set arbitrarily between 0 and 590Hz. Constant torque or variable torque modes are selectable, and V/F is adjustable in 5 points. | ||
Starting Torque | Induction Motor | 120% 0.5Hz (with Advanced Flux Vector Control) | |
IPM Motor | 50% | ||
Torque Boost | Manual Torque Boost | ||
Acceleration/Deceleration Time Setting | 0~3600s (acceleration and deceleration times can be set separately) Linear, S-shaped acceleration/deceleration modes, backlash prevention acceleration/deceleration | ||
DC braking (induction motor) | Action frequency (0~120Hz), action time (0~10s), action voltage (0~30%) are variable | ||
Stalling prevention action level | Stalling prevention action level action range (SLD rated: 0~120%, LD rated: 0~150%), selectable with or without. | (V/F control, advanced flux vector control) ||
Operating characteristics | Frequency setting signal | Analog input | Torque limit value can be set (0~400% variable); (Real-time sensorless vector control, vector maximum control, PM sensorless vector control) |
Digital input | Terminals 2 and 4: Selectable between 0~10V, 0~5V, and 4~20mA (0~20mA). Terminal 1: Selectable between -10~H0V and -5~+5V. | ||
Start Signal | Input via the M knob and parameter unit on the operation panel; BCD 4-bit or 16-bit binary number (when using option FR-A8AX) | ||
Input Signal (12 points) | Low speed operation command, medium speed operation command, high speed operation command, second function selection, terminal 4 input selection, JOG operation selection, output stop, start self-hold selection, forward rotation command, reverse rotation command, inverter reset. The input signal can be changed via Pr.178~Pr.189 (input terminal function selection). | ||
Pulse train input | lOOkpps | ||
Run function | Upper limit frequency, lower limit frequency, multi-speed operation, acceleration/deceleration curve, overheat protection, DC braking, starting frequency, JOG operation, output stop (MRS), stall prevention, regenerative avoidance, strong excitation deceleration, DC power supply, frequency jump, speed display, instantaneous stop and restart, power frequency switching sequential control, remote control setting, retry. function, carrier frequency selection, high response current limit, forward and reverse rotation prevention, operating mode selection, slip compensation, distance smoothing control, triangular wave, automatic tuning, applicable motor selection, RS-485 communication, PID control, PID pre-charge function, cooling fan action selection, stop selection (deceleration stop/free operation), deceleration stop function. during power failure, sequential control function, life diagnosis, maintenance timer, average current monitoring, multiple ratings, test run, 24V power input for control loop, safety stop function, self-powered management, BACnet communication, PID gain tuning, sweep function, load characteristic storage, emergency drive. | ||
| rowspan="2"> Output Signals | Open Collector Output (5 points) Relay Output (2 points) | Inverter operation, frequency reached, momentary power outage/insufficient voltage, overload alarm, output frequency detection, abnormality; output signals can be changed via Pr.190~Pr.196 (output terminal function selection). The inverter's alarm code can be output via open collector (4 bits). | |
Pulse Train Output (FM Type) | 50kpps | ||
Display | Display Calculation | Pulse Train Output (FM Type) | Maximum 2.4kHz: 1 point (output frequency); can be selected and monitored via Pr.54 FM/CA terminal function. |
Current Output (CA Type) | Maximum DC20mA: 1 point (output frequency); can be selected and monitored via Pr.54 FM/CA terminal function. | ||
Voltage Output | Maximum DC10V: 1 point (output frequency); can be changed and monitored via Pr.158 AM terminal function selection. | ||
Operation Panel (FR-DU08) | Operating Status | Output frequency, output current, output voltage, frequency setpoint/speed setpoint can be changed and monitored via Pr.52 operation panel main display. | |
Abnormal Content | Displays abnormal content when protection function is activated, stores 8 abnormal contents and the output voltage, current, frequency, cumulative power-on time, year, month, day, and time before the protection function action. | ||
Protection/Alarm Functions | Protection Functions | Overcurrent Trip during Acceleration, Overcurrent Trip during Constant Speed, Overcurrent Trip during Deceleration/Stop, Regenerative Overvoltage Trip during Acceleration, Regenerative Overvoltage Trip during Constant Speed, Regenerative Overvoltage Trip during Deceleration/Stop, Inverter Overload Trip (Electronic Overheat Protection), Motor Overload Trip (Electronic Overheat Protection), Heatsink Overheat, Instantaneous Power Outage and Insufficient. Voltage W, Input Phase Loss M, Stopped Due to Disconnection Prevention, Offset Detection, Upper Limit Fault Detection, Lower Limit Fault Detection, Output Side Ground Short Circuit Overcurrent, Output Phase Loss, External Thermal Relay Operation, PTC Thermistor Operation The following are possible errors/problems: Option malfunction, communication option malfunction, inverter parameter. storage component malfunction, PU disconnection, retry count overflow, CPU error, short circuit in the power supply to the operation panel/RS-485 terminal, DC24V power supply malfunction, abnormal output current detection value, abnormal surge current suppression circuit, communication malfunction (host), abnormal analog input, abnormal USB communication, abnormal safety circuit, excessive. distance occurrence, 4mA input loss malfunction, abnormal PID precharge, abnormal PID signal, abnormal internal circuit, user-defined sequential control function malfunction. | |
Alarm Functions | Fan Failure, Remote Failure Prevention (Overcurrent), Remote Failure Prevention (Overcurrent), Electronic Overheat Protection Prediction, PU Stop, Parameter Copy, Safety Stop, Maintenance Timer 1-3, USB Host Abnormality, Operation Panel Lock, Password Setting, Parameter Write Error, Copy Operation Error, 24V External Power Supply in Action, Load Abnormality Alarm, Emergency Drive Execution | ||
Ambient Temperature | Ambient Temperature | —10aC~+5CTC (Non-icing) (LD rated);—10aC~+40 (Non-icing) (SLD rated) | |
Ambient Humidity | |||
Altitude: Below 1000m, below 5.9ra/s², 10~55Hz (X, Y, Z directions) |
Model | FR-F840-02600-2-60 | ||
Applicable motor capacity (kW) | SLD | 132 | |
LD | 110 | ||
Output | Rated Capacity (kVA) | SLD | 198 |
LD | 165 | ||
Rated Current (A) | SLD | 260 | |
LD | 216 | ||
Overload Capacity | SLD | 110% 60 seconds, 120% 3 seconds (Inverse Time Characteristic) (Ambient Temperature 40°C) | |
LD | 120% 60 seconds, 150% 3 seconds (Inverse Time Characteristic) (Ambient Temperature 50°C) | ||
Rated Voltage | 3-phase 380 - 500V | ||
Power Supply | Rated Input: AC Voltage & Frequency | 3-phase 380 - 500V 50Hz/60Hz | |
Allowable AC Voltage Fluctuation Range | 323 - 500V 50Hz/60Hz | ||
Allowable Frequency Fluctuation Range | ±5% | ||
Rated Input Current (A) | SLD | 260 | |
LD | 216 | ||
Power supply capacity (kVA) | SLD | 198 | |
LD | 165 | ||
Protective structure (JEM 1030) | Open (IP00) | ||
Cooling Method | Forced Air Cooling | ||
Approximate Weight (kg) | 55 |
Technical Specifications
| Specification | Value |
|---|---|
| Brand | Mitsubishi Electric |
| Series | FR-F840 |
| Number of Phases | Three-phase | td>
| Rated Power (kW) | 110 |
| Rated Output Current (A) | 216A |
| Input Voltage (V) | 400V |
| Operation Panel | Included |
Plain language sourcing guide for Mitsubishi Electric ELECTRIC inverter, FR-F840-02600-2-60
Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.
Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.
Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.
If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.
Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.
Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.
Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.
Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.
For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.
For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.
For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.
| Brand Name: | Mitsubishi | Certification: | ISO9001, CE |
|---|---|---|---|
| Place of Origin: | China | Condition: | New |
| Warranty: | 1 year | Customized sourcing: | available |
What are your strengths?
Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.
What is your estimated delivery time?
Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.
What are your primary product offerings?
Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.
How can I get in touch with you?
Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.
What are your payment terms?
Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.
Feel free to Ask questions
Mitsubishi Electric ELECTRIC inverter, FR-F840-02600-2-60
Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.
For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.
Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.
Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.
- Confirm the complete model number and any suffix printed on the nameplate.
- Share quantity, destination country, preferred shipping method, and target delivery date.
- Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
- Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.
Useful details for a faster quote
- Complete model and part number
- Required quantity and target delivery date
- Nameplate photos, drawings, or old purchase records
- Voltage, signal range, dimensions, or accessory needs
Model matching
We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.
Quality and delivery
Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.
Stock alternatives
For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.
Mitsubishi Electric ELECTRIC inverter, FR-F840-02600-2-60 verification notes
Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.
LEHIY reviews product name, part number, series, label information, and application requirements before shipment.
If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.
For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.
Related Products
Explore More
More In This Category
Trusted partners
We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.