Mitsubishi Electric ELECTRIC inverter, FR-F840-00083-2-60

LEHIY item code: LH-0777

Ambient Temperature: Ambient Temperature

Category: Mitsubishi Electric ELECTRIC inverter

Rated voltage: 3-phase 380 - 500V

Quick buying check

This page helps you check Mitsubishi Electric ELECTRIC inverter, FR-F840-00083-2-60 before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

Technical Specifications

Below 95%RH (non-condensing) (with circuit board coating (corresponding to IEC60721-3-33C2_/3S2)); Below 90%RH (non-condensing) (without circuit board coating)

Storage Temperature

-20℃~+65℃

Ambient Environment

Indoor (free from corrosive gases, flammable gases, oil mist, dust, etc.)

Altitude • Vibration

(V/F control, advanced flux vector control)

Control Characteristics

Control Methods

Soft-PWM Control/High Carrier Frequency PWM Control (Selectable V/F Control (Optimal Excitation Control, etc.), Advanced Flux Vector Control (Optimal Excitation Control, etc.), PM Motor Control)

Output Frequency Range

0.2~590Hz (with an upper limit of 400Hz for Advanced Flux Vector Control and PM Motor Control.)

Frequency Setting Resolution

Analog Input

0.015Hz/60Hz (Terminals 2, 4: 0~10V/12bit)

0.03Hz/60Hz (Terminals 2, 4: 0~5V/11 bit, 0~20mA/approx. 11 bit, Terminal 1: 0~±10V/12bit)

0.06Hz/60Hz (Terminal 1: 0~±5V/11 bit)

Digital Input

0.01Hz

Frequency Accuracy

Analog Input

Maximum output frequency within ±0.2% (25℃±10℃)

Digital input

Set output frequency within 0.01%

Voltage/frequency characteristics

The reference frequency can be set arbitrarily between 0 and 590Hz. Constant torque or variable torque modes are selectable, and V/F is adjustable in 5 points.

Starting Torque

Induction Motor

120% 0.5Hz (with Advanced Flux Vector Control)

IPM Motor

50%

Torque Boost

Manual Torque Boost

Acceleration/Deceleration Time Setting

0~3600s (acceleration and deceleration times can be set separately) Linear, S-shaped acceleration/deceleration modes, backlash prevention acceleration/deceleration

DC braking (induction motor)

Action frequency (0~120Hz), action time (0~10s), action voltage (0~30%) are variable

Stalling prevention action level

Stalling prevention action level action range (SLD rated: 0~120%, LD rated: 0~150%), selectable with or without.

Operating characteristics

Frequency setting signal

Analog input

Torque limit value can be set (0~400% variable); (Real-time sensorless vector control, vector maximum control, PM sensorless vector control)

Digital input

Terminals 2 and 4: Selectable between 0~10V, 0~5V, and 4~20mA (0~20mA). Terminal 1: Selectable between -10~H0V and -5~+5V.

Start Signal

Input via the M knob and parameter unit on the operation panel; BCD 4-bit or 16-bit binary number (when using option FR-A8AX)

Input Signal (12 points)

Low speed operation command, medium speed operation command, high speed operation command, second function selection, terminal 4 input selection, JOG operation selection, output stop, start self-hold selection, forward rotation command, reverse rotation command, inverter reset.

The input signal can be changed via Pr.178~Pr.189 (input terminal function selection).

Pulse train input

lOOkpps

Run function

Upper limit frequency, lower limit frequency, multi-speed operation, acceleration/deceleration curve, overheat protection, DC braking, starting frequency, JOG operation, output stop (MRS), stall prevention, regenerative avoidance, strong excitation deceleration, DC power supply, frequency jump, speed display, instantaneous stop and restart, power frequency switching sequential control, remote control setting, retry.

function, carrier frequency selection, high response current limit, forward and reverse rotation prevention, operating mode selection, slip compensation, distance smoothing control, triangular wave, automatic tuning, applicable motor selection, RS-485 communication, PID control, PID pre-charge function, cooling fan action selection, stop selection (deceleration stop/free operation), deceleration stop function.

during power failure, sequential control function, life diagnosis, maintenance timer, average current monitoring, multiple ratings, test run, 24V power input for control loop, safety stop function, self-powered management, BACnet communication, PID gain tuning, sweep function, load characteristic storage, emergency drive.

rowspan="2">

Output Signals

Open Collector Output (5 points)

Relay Output (2 points)

Inverter operation, frequency reached, momentary power outage/insufficient voltage, overload alarm, output frequency detection, abnormality; output signals can be changed via Pr.190~Pr.196 (output terminal function selection). The inverter's alarm code can be output via open collector (4 bits).

Pulse Train Output (FM Type)

50kpps

Display

Display Calculation

Pulse Train Output (FM Type)

Maximum 2.4kHz: 1 point (output frequency); can be selected and monitored via Pr.54 FM/CA terminal function.

Current Output (CA Type)

Maximum DC20mA: 1 point (output frequency); can be selected and monitored via Pr.54 FM/CA terminal function.

Voltage Output

Maximum DC10V: 1 point (output frequency); can be changed and monitored via Pr.158 AM terminal function selection.

Operation Panel (FR-DU08)

Operating Status

Output frequency, output current, output voltage, frequency setpoint/speed setpoint can be changed and monitored via Pr.52 operation panel main display.

Abnormal Content

Displays abnormal content when protection function is activated, stores 8 abnormal contents and the output voltage, current, frequency, cumulative power-on time, year, month, day, and time before the protection function action.

Protection/Alarm Functions

Protection Functions

Overcurrent Trip during Acceleration, Overcurrent Trip during Constant Speed, Overcurrent Trip during Deceleration/Stop, Regenerative Overvoltage Trip during Acceleration, Regenerative Overvoltage Trip during Constant Speed, Regenerative Overvoltage Trip during Deceleration/Stop, Inverter Overload Trip (Electronic Overheat Protection), Motor Overload Trip (Electronic Overheat Protection), Heatsink Overheat, Instantaneous Power Outage and Insufficient.

Voltage W, Input Phase Loss M, Stopped Due to Disconnection Prevention, Offset Detection, Upper Limit Fault Detection, Lower Limit Fault Detection, Output Side Ground Short Circuit Overcurrent, Output Phase Loss, External Thermal Relay Operation, PTC Thermistor Operation The following are possible errors/problems: Option malfunction, communication option malfunction, inverter parameter.

storage component malfunction, PU disconnection, retry count overflow, CPU error, short circuit in the power supply to the operation panel/RS-485 terminal, DC24V power supply malfunction, abnormal output current detection value, abnormal surge current suppression circuit, communication malfunction (host), abnormal analog input, abnormal USB communication, abnormal safety circuit, excessive.

distance occurrence, 4mA input loss malfunction, abnormal PID precharge, abnormal PID signal, abnormal internal circuit, user-defined sequential control function malfunction.

Alarm Functions

Fan Failure, Remote Failure Prevention (Overcurrent), Remote Failure Prevention (Overcurrent), Electronic Overheat Protection Prediction, PU Stop, Parameter Copy, Safety Stop, Maintenance Timer 1-3, USB Host Abnormality, Operation Panel Lock, Password Setting, Parameter Write Error, Copy Operation Error, 24V External Power Supply in Action, Load Abnormality Alarm, Emergency Drive Execution

Ambient Temperature

Ambient Temperature

—10aC~+5CTC (Non-icing) (LD rated);—10aC~+40 (Non-icing) (SLD rated)

Ambient Humidity

Altitude: Below 1000m, below 5.9 m/s², 10~55 Hz (X, Y, Z directions)

Note:

  1. Some protection and alarm functions are only effective for standard construction products.

  2. Initially, some protection and alarm functions are ineffective.

  3. Temperatures suitable for short periods such as during transportation.

  4. When installing at altitudes above 1000m (maximum 2500m), the rated current needs to be reduced by 3% for every 500m increase in altitude.

  5. FR-F840-0-1320 (185K) and above are 2.9 m/s² and below.

Model

FR-F840-00083-2-60

Applicable motor capacity (kW)

SLD

3.7

LD

3.7

Output

Rated capacity (kVA)

SLD

6.3

LD

5.8

Rated current (A)

SLD

8.3

LD

7.6

Overload capability

SLD

110% 60 seconds, 120% 3 seconds (inverse time characteristic) (Ambient temperature 40°C)

LD

120% 60 seconds, 150% 3 seconds (inverse time characteristic) (Ambient temperature 50°C)

Rated voltage

3-phase 380 - 500V

Power supply

Rated input: AC voltage and frequency

3-phase 380 - 500V 50Hz/60Hz

Allowable AC Voltage Fluctuation Range

323 - 500V 50Hz/60Hz

Allowable Frequency Fluctuation Range

±5%

Rated Input Current (A)

SLD

10.9

LD

10.1

Power Supply Capacity (kVA)

SLD

8.3

LD

7.7

Protective Structure (JEM 1030)

Enclosed (IP20)

Cooling Method

Forced Air Cooling

Approximate Weight (kg)

3.0

Note:

  1. General motor capacity refers to the maximum applicable capacity when using a Mitsubishi standard 4-pole motor.

  2. Rated output capacity refers to the output voltage at 440V.

  3. The % value of the rated overload current represents the ratio to the rated output current of the inverter. When using repeatedly, you must wait until the inverter and motor cool down to below the temperature at 100% load.

  4. The maximum output voltage cannot exceed the power supply voltage. The maximum output voltage can be changed within the set range. However, the peak voltage on the inverter output side is approximately 1.41 times the power supply voltage.

  5. Rated input current is the value at the rated output current. The rated input current varies with the value of the power supply reactance (including the input reactor and wiring).

  6. Power supply capacity is a value under rated current output conditions, which varies with the impedance on the power supply side (including the input reactor and wiring).

  7. Protection structure: FR-DU08: IP40 (except for the PU interface).

  8. For voltages exceeding 480V, the Pr977 input voltage mode selection must be set.


Technical Specifications

>
SpecificationValue
BrandMitsubishi Electric
SeriesFR-F840
Number of PhasesThree-phase
Rated Power (kW)3.7
Rated Output Current (A)7.6A
Input Voltage (V)380~500V
Operation PanelIncluded

Plain language sourcing guide for Mitsubishi Electric ELECTRIC inverter, FR-F840-00083-2-60

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:MitsubishiCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

Mitsubishi Electric ELECTRIC inverter, FR-F840-00083-2-60

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

Mitsubishi Electric ELECTRIC inverter, FR-F840-00083-2-60 verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo
fusheng logo