Mitsubishi FR-D720-5.5K Japanese standard 5.5KW inverter, original import from Japan.
LEHIY item code: LH-0227
Quick buying check
This page helps you check Mitsubishi FR-D720-5.5K Japanese standard 5.5KW inverter, original import from Japan. before you ask for a quote.
Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.
LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.
| Common Specifications | |||
| Control Characteristics | Control Mode | Soft-PWM control/high carrier frequency PWM control (magnetic vector control for V/F control sink, optimal excitation control optional) | |
| Output Frequency Range | 0.2~400Hz | ||
| Frequency setting resolution | Analogous input | 0.06Hz/60Hz (terminals 2 × 4:0~10V/10bit) 0.12Hz/60Hz (terminals 2 × 4:0~5V/9bit) 0.06Hz/60Hz (terminals 4:0 ~ 20mA/10bit) | |
| Digital Input | 0.01Hz | ||
| Frequency Accuracy | Analogous input | Within ± 1% of maximum output frequency (25°C ± 10°C) | |
| Digital Input | Set the output frequency to within 0.01 percent | ||
| Voltage/Frequency Characteristics | base frequency 0 ~~ 400Hz can be arbitrarily set constant torque, variable torque can be selected | ||
| Open torque | 150% or more (at 1Hz).......... When setting magnetic beam vector control and slip correction for flood season use | ||
| Torque boost | Manual torque boost | ||
| Acceleration/Deceleration Time Setting | 0.1~3600s (individual setting of acceleration and deceleration is possible), direct or S-shaped acceleration and deceleration mode can be selected | ||
| DC Brake | Variable operating frequency (0~120Hz), operating time (0~10s) and operating voltage (0 ~ 30%) | ||
| Stall Prevention Action Position | The operating current level can be set (0~200% variable) and can be selected with or without | ||
| Running Characteristics | Frequency setting signal | Analogous input | 2-point terminals 2:0~10V × 0~5V selectable possible terminals 4:0~10V × 0~5V × 4 ~ 20mA selectable possible |
| Digital Input | Operation panel, parameter unit input, frequency setting unit selectable | ||
| Rest signal | Self-hold input (3-wire input) of forward rotation, reverse rotation and loss signals can be selected | ||
| Input signal | 5-point multi-stage speed selection, remote setting, second function selection, terminal 4 input selection, JOG operation selection, PID control effective terminal, external electrothermal glow input, PU-external operation switching, V/F switching, output stop, failure self-hold selection, forward rotation, reverse command, inverter reset, PU-NET operation switching external-NET operation switching, command right switching, dual frequency device operation permission signal, PU operation/external operation interlock signal. | ||
| Operating function | upper and lower limit frequency setting, frequency jump operation, external thermal power station input selection, instantaneous stop and re-enemy operation, forward rotation and reverse prevention, remote setting, brake program, second function, multi-stage speed operation, recovery avoidance, slip correction, operation mode selection, OFF-Line automatic tuning, PID control, computer connection operation (RS-485), optimal excitation control, power failure stop, speed smoothing control, Modbus-RTU | ||
| John Out Signal | Number of outgoing signals | Open collector transistor output | 1 point |
| Relay output | 1 point | ||
| Running status | inverter is in operation, frequency arrival, overload alarm, output frequency detection, retrograde brake warning report, electronic thermal power station warning report, inverter operation preparation, output current detection, zero current detection, PID lower limit, PID upper limit, PID forward rotation and reverse output, cooling fan failure, radiator overheating warning report, power failure deceleration, PID during control action, PID output interruption, retry action, part life alarm, current average monitoring, remote output, abnormal output, abnormal output 3, light fault output, miscellaneous maintenance time alarm | ||
| Indicates the number of output points for the meter | Analogous output | 0 to 10V DC:1 point | |
| Indicates | output frequency, motor current, output voltage, frequency set value, motor torque, converter output voltage, regenerative brake utilization rate, electronic thermal relay load rate, output current peak value, converter output voltage peak value, reference voltage output, motor load rate, PID target value, PID measurement value, output power SPID deviation, motor heat load rate, frequency converter heat load rate, 0 ~ 10VD output. | ||
| Display | Operator Panel Parameter Unit (FR-PU07) | Running status | output frequency, motor current, output voltage, frequency setting value, motor torque, converter output voltage, regenerative brake usage rate, electronic product thermal relay load rate, output current peak value, converter output voltage peak value, reference voltage output, motor load rate, PID target value, PID measurement value, output power deviation, inverter output input terminal monitoring, optional output terminal monitoring, output power, power accumulation, motor heat load rate, inverter heat load rate, PTC thermistor. |
| Exception content | |||
| Additional parameter unit function (FR-PU04/FR-PU07) | Running status | None | |
| Exception content | the output voltage, current, frequency and over-current time of the protection function before operation are accumulated. | ||
| Conversational guidance | Help function for guidance | ||
| Protection and Alarm Function | & lt; protection function & gt; overcurrent in acceleration_overcurrent in constant speed, overcurrent in deceleration, overvoltage in acceleration, overvoltage in deceleration, overvoltage in constant speed, inverter accumulation thermoelectric protection, motor overcurrent protection, radiator overheating, input underphase, output side grounding overcurrent during starting, output underphase, external accumulation thermoelectric relay operating PTC thermistor action, parameter abnormality, PU shedding occurrence, retry times, CPU abnormality, brake crystal abnormality 1. Overheating of inrush resistor, abnormal analog input signal, stall prevention, output current detection value exceeding & lt; alarm function & gt; fan failure * 2, over-current stall prevention, over-voltage stall prevention, PU stop, parameter writing error, regenerative brake warning report, electronic thermal power station warning report, maintenance signal output, insufficient voltage, operation panel lock, password lock, inverter reset. | ||
| Environment | Ambient temperature | -10 ℃ ~ +50 ℃ (no freezing)(-10 ℃ ~ +40 ℃ full-lock structure specification) * 3 | |
| Ambient humidity | Below 90% RH (no condensation) | ||
| Storage temperature * 1 | -20℃~+65℃ | ||
| Atmosphere | Inside the house (free of corrosive gas, flammable gas, oil mist, dust, etc.) | ||
| Elevation · Vibration | Altitude below 1000m · below 5.9 m/s ² |
| ● 3-phase 200V supply | ||||||||||
| Type FR-D720-□ | 0.1 | 0.2 | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | |
| Applicable motor capacity (kW(HP))* 1 | 0.1 (1/8) | 0.2 (1/4) | 0.4 (1/2) | 0.75 (1) | 1.5 (2) | 2.2 (3) | 3.7 (5) | 5.5 (7.5) | 7.5 (10) | |
| John out | Rated capacity (kVA)* 2 | 0.3 | 0.6 | 1.0 | 1.7 | 2.8 | 4.0 | 6.6 | 9.5 | 12.7 |
| Current rating (A) | 0.8 | 1.4 | 2.5 | 4.2 | 7.0 | 10.0 | 16.5 | 23.8 | 31.8 | |
| Overload rated current * 3 | 150%60s,200%0. 5S (inverse time-limited characteristic) | |||||||||
| Voltage * 4 | 3-phase 200~240V | |||||||||
| Power | Rated input AC voltage/frequency | 3-phase 200~240V 50Hz/60Hz | ||||||||
| Allowable AC Voltage Variation | 170~264V 50Hz/60Hz | |||||||||
| Allowable frequency variation | ±5% | |||||||||
| Power supply capacity (kVA)* 5 | 0.4 | 0.7 | 1.2 | 2.1 | 4.0 | 5.5 | 9.0 | 12.0 | 17.0 | |
| Protection construct (JEM1030) | Locking (IP 20) | |||||||||
| Cooling method | Self-cooling | Forced air cooling | ||||||||
| approximate mass (kg) | 0.5 | 0.5 | 0.8 | 1.0 | 1.4 | 1.4 | 1.8 | 3.6 | 3.6 | |
| ● 3-phase 400V supply | ||||||||||
| Form FR-D740-□ | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | 7.5 | |||
| Applicable motor capacity (kW(HP))* 1 | 0.4 (1/2) | 0.75 (1) | 1.5 (2) | 2.2 (3) | 3.7 (5) | 5.5 (7.5) | 7.5 (10) | |||
| Rated capacity (kVA)* 2 | 0.9 | 1.7 | 2.7 | 3.8 | 6.1 | 9.1 | 12.2 | |||
| Current rating (A) | 1.2 | 2.2 | 3.6 | 5.0 | 8.0 | 12.0 | 16.0 | |||
| Overload rated current 3 | 150%60s,200%0. 5S (inverse time-limited property) | |||||||||
| Voltage * 4 | 3-phase 380~480V | |||||||||
| Power | Rated input AC voltage/frequency | 3-phase 380~480V 50Hz/60Hz | ||||||||
| Allowable AC Voltage Variation | 325~528V 50Hz/60Hz | |||||||||
| Allowable frequency variation | ±5% | |||||||||
| Power supply capacity (kVA)* 5 | 1.5 | 2.5 | 4.5 | 5.5 | 9.5 | 12.0 | 17.0 | |||
| Protection construct (JEM1030) | Latching (IP20) | |||||||||
| Cooling method | Self-cooling | Forced air cooling | ||||||||
| approximate mass (kg) | 1.3 | 1.3 | 1.4 | 1.5 | 1.5 | 3.3 | 3.3 | |||
| * 1 The applicable motor is the maximum applicable capacity of the Mitsubishi standard 4-pole motor. | ||||||||||
| * 2230V voltage output is 200V voltage level inverter, 440V voltage output is 400V voltage level inverter. | ||||||||||
| * 3 The% value of the overload current rating represents the ratio relative to the rated output current of the inverter. Repeated use must wait for the frequency converter and motor to drop below the temperature at 100 percent load. * 4 & nbsp; The maximum output voltage cannot be higher than the power supply voltage. The maximum output voltage can be changed within the setting range. The peak value of the inverter output voltage is about √ 2 times of the power supply voltage. * 5 The power supply capacity varies with the measured impedance (including input reactors and wires) of the power supply. |
| ● Single-phase 200V supply | |||||||
| Form FR-D720S-□ | 0.1 | 0.2 | 0.4 | 0.75 | 1.5 | 2.2 | |
| Applicable motor capacity (kW(HP))* 1 | 0.1 (1/8) | 0.2 (1/4) | 0.4 (1/2) | 0.75 (1) | 1.5 (2) | 2.2 (3) | |
| John out | Rated capacity (kVA)* 2 | 0.3 | 0.6 | 1.0 | 1.7 | 2.8 | 4.0 |
| Current rating (A) | 0.8 | 1.4 | 2.5 | 4.2 | 7.0 | 10.0 | |
| Overload rated current * 3 | 150%60s,200%0. 5S (inverse time-limited property) | ||||||
| Voltage * 4 | 3-phase 200~240V | ||||||
| Power | Rated input AC voltage/frequency | Single-phase 200 to 240V 50Hz/60Hz | |||||
| Allowable AC Voltage Variation | 170~264V 50Hz/60Hz | ||||||
| Allowable frequency variation | ±5% | ||||||
| Power supply capacity (kVA)* 5 | 0.5 | 0.9 | 1.5 | 2.3 | 4.0 | 5.2 | |
| Protection construct (JEM1030) | Latching (IP20) | ||||||
| Cooling method | Self-cooling | Forced air cooling | |||||
| Approximate mass (kg) | 0.5 | 0.5 | 0.9 | 1.1 | 1.5 | 2.0 | |
| ● Single-phase 100V supply | |||||||
| Form FR-D710W-□ | 0.1 | 0.2 | 0.4 | 0.75 | |||
| Applicable motor capacity (kW(HP))* 1 | 0.1 (1/8) | 0.2 (1/4) | 0.4 (1/2) | 0.75 (1) | |||
| John out | Rated capacity (kVA)* 2 | 0.3 | 0.6 | 1.0 | 1.7 | ||
| Current rating (A) | 0.8 | 1.4 | 2.5 | 4.2 | |||
| Overload rated current * 3 | 150%60s,200%0. 5S (inverse time-limited characteristic) | ||||||
| Voltage * 4 | 3-phase 200~230V * 6,* 7 | ||||||
| Power | Rated input AC voltage/frequency | 100~115V 50Hz/60Hz | |||||
| Allowable AC Voltage Variation | 90~132V 50Hz/60Hz | ||||||
| Allowable frequency variation | ±5% | ||||||
| Power supply capacity (kVA)* 5 | 0.5 | 0.9 | 1.5 | 2.5 | |||
| Protection construct (JEM1030) | Latching (IP20) | ||||||
| Cooling method | Self-cooling | ||||||
| Approximate mass (kg) | 0.6 | 0.7 | 0.9 | 1.4 | |||
| * 1 The applicable motor is the maximum applicable capacity of the Mitsubishi standard 4-pole motor. * 2 rated output capacity, the output voltage is 230V. | |||||||
| * 3 The% value of the overload rated current indicates the ratio relative to the rated current of the inverter. Repeated use must wait for the frequency converter and motor to drop below the temperature at 100 percent load. * 4 & nbsp; The maximum output voltage cannot be higher than the power supply voltage. The maximum output voltage can be changed within the setting range. However, the peak value of the voltage waveform of the inverter is about √ 2 times * 5 of the power supply voltage. the power supply capacity changes with the impedance (including input reactor and wire) value on the power supply side. * 6 single-phase 100V input specifications, the maximum output voltage is 2 times the power supply voltage, can not exceed. |
| Model | Power (KW) | W | H | D | D2 | Weight | Version |
| Three-phase 220V | FR-D720-0.1K | 0.1 | 68 | 128 | 80.5 | 0.5 | Japanese |
| FR-D720-0.2K | 0.2 | 68 | 128 | 80.5 | 0.5 | Japanese | |
| FR-D720-0.4K | 0.4 | 68 | 128 | 112.5 | 0.8 | Japanese | |
| FR-D720-0.75K | 0.75 | 68 | 128 | 132.5 | 1.0 | Japanese | |
| FR-D720-1.5K | 1.5 | 108 | 128 | 135.5 | 1.4 | Japanese | |
| FR-D720-2.2K | 2.2 | 108 | 128 | 135.5 | 1.4 | Japanese | |
| FR-D720-3.7K | 3.7 | 170 | 128 | 142.5 | 1.8 | Japanese | |
| FR-D720-5.5K | 5.5 | 220 | 150 | 155 | 3.6 | Japanese | |
| FR-D720-7.5K | 7.5 | 220 | 150 | 155 | 3.6 | Japanese | |
| FR-D720-11K | 11 | Japanese | |||||
| FR-D720-15K | 15 | Japanese | |||||
| Single phase 220V | FR-D720S-0.1K-CHT | 0.1 | 68 | 128 | 80.5 | 0.5 | Medium |
| FR-D720S-0.2K-CHT | 0.2 | 68 | 128 | 80.5 | 0.6 | Medium | |
| FR-D720S-0.4K-CHT | 0.4 | 68 | 128 | 142.5 | 0.9 | Medium | |
| FR-D720S-0.75K-CHT | 0.75 | 68 | 128 | 162.5 | 1.1 | Medium | |
| FR-D720S-1.5K-CHT | 1.5 | 108 | 128 | 155.5 | 1.5 | Medium | |
| FR-D720S-2.2K-CHT | 2.2 | 140 | 150 | 145 | 1.9 | Medium |
| Model | Power (KW) | W | H | D | D2 | Weight | Version |
| FR-D720-0.1K | 0.1 | 68 | 128 | 80.5 | 0.5 | Japanese | |
| FR-D720-0.2K | 0.2 | 68 | 128 | 80.5 | 0.5 | Japanese | |
| FR-D720-0.4K | 0.4 | 68 | 128 | 112.5 | 0.8 | Japanese | |
| FR-D720-0.75K | 0.75 | 68 | 128 | 132.5 | 1.0 | Japanese | |
| FR-D720-1.5K | 1.5 | 108 | 128 | 135.5 | 1.4 | Japanese | |
| FR-D720-2.2K | 2.2 | 108 | 128 | 135.5 | 1.4 | Japanese | |
| FR-D720-3.7K | 3.7 | 170 | 128 | 142.5 | 1.8 | Japanese | |
| FR-D720-5.5K | 5.5 | 220 | 150 | 155 | 3.6 | Japanese | |
| FR-D720-7.5K | 7.5 | 220 | 150 | 155 | 3.6 | Japanese | |
| FR-D720-11K | 11 | Japanese | |||||
| FR-D720-15K | 15 | Japanese | |||||
| FR-D720-008-NA | 0.1 | 68 | 128 | 80.5 | 0.5 | European | |
| FR-D720-014-NA | 0.2 | 68 | 128 | 80.5 | 0.5 | European | |
| FR-D720-025-NA | 0.4 | 68 | 128 | 112.5 | 0.8 | European | |
| FR-D720-042-NA | 0.75 | 68 | 128 | 132.5 | 1.0 | European | |
| FR-D720-070-NA | 1.5 | 108 | 128 | 135.5 | 1.4 | European | |
| FR-D720-100-NA | 2.2 | 108 | 128 | 135.5 | 1.4 | European | |
| FR-D720-165-NA | 3.7 | 170 | 128 | 142.5 | 1.8 | European | |
| FR-D720-238-NA | 5.5 | 220 | 150 | 155 | 3.6 | European | |
| FR-D720-318-NA | 7.5 | 220 | 150 | 155 | 3.6 | European |
Plain language sourcing guide for Mitsubishi FR-D720-5.5K Japanese standard 5.5KW inverter, original import from Japan.
Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.
Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.
Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.
If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.
Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.
Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.
Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.
Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.
For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.
For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.
For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.
| Brand Name: | Mitsubishi | Certification: | ISO9001, CE |
|---|---|---|---|
| Place of Origin: | China | Condition: | New |
| Warranty: | 1 year | Customized sourcing: | available |
What are your strengths?
Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.
What is your estimated delivery time?
Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.
What are your primary product offerings?
Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.
How can I get in touch with you?
Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.
What are your payment terms?
Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.
Feel free to Ask questions
Mitsubishi FR-D720-5.5K Japanese standard 5.5KW inverter, original import from Japan.
Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.
For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.
Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.
Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.
- Confirm the complete model number and any suffix printed on the nameplate.
- Share quantity, destination country, preferred shipping method, and target delivery date.
- Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
- Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.
Useful details for a faster quote
- Complete model and part number
- Required quantity and target delivery date
- Nameplate photos, drawings, or old purchase records
- Voltage, signal range, dimensions, or accessory needs
Model matching
We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.
Quality and delivery
Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.
Stock alternatives
For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.
Mitsubishi FR-D720-5.5K Japanese standard 5.5KW inverter, original import from Japan. verification notes
Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.
LEHIY reviews product name, part number, series, label information, and application requirements before shipment.
If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.
For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.
Related Products
Explore More
More In This Category
Trusted partners
We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.