../../images-webp/4cfc36ff7ea609b0334c5b2ee6f1a9d5.webp
../../images-webp/4cfc36ff7ea609b0334c5b2ee6f1a9d5.webp

E+H tuning fork level switch, FTL31-AA4U2AAWBJ

Industrial switch for sensing or control applications.
In Stock & ready to ship

Product Overview

Li ... FTL31 liquid limit switches are suitable for measurement in all industries, primarily the machinery industry.

Features

Liquiphant FTL31 liquid limit switches are suitable for overflow protection and pump dry running protection in cleaning, filtration systems, and cooling and lubrication containers.

Compact: - Smallest tuning fork sensor on the market. Safe: - Continuous self-monitoring. - Reliable switching action, unaffected by media properties. Simple: - No calibration or adjustment required. - Plug and play.

Liquiphant FTL31 liquid limit switches are suitable for measurement in all industries, primarily the machinery industry. Liquiphant can be used for overflow protection and pump dry running protection in cleaning, filtration systems, and cooling and lubrication containers.

  • Works based on tuning fork measurement principle, safe and reliable operation, wide range of applications

  • Rugged and durable stainless steel housing (316L) for maximum durability

  • External function testing via test magnet

  • Uses LED Indicator Lights for On-Site Function Testing

  • Compact design allows for easy installation and use in confined spaces

  • Designed to meet the highest quality and environmental sustainability requirements. The self-monitoring Liquidant ensures safe switching even during power outages.

  • Unaffected by changes in media characteristics, providing precise switching points

  • Even in environments with changing media, no adjustment is required; this plug-and-play sensor is practically usable.

  • Measurements are unaffected by conductivity, adhesion, disturbance, flow, or bubbles.
  • No calibration required, no specific knowledge or tools (e.g., software) needed.

  • Modular design provides different process temperatures and the widest variety of process connections and accessories on the market to meet every application requirement.

  • No moving mechanical parts, maintenance-free.

Technical Specifications

°F ... 302 °F) prevention WHG

Measurement Principle

Liquid Tuning Fork

Features/Applications

Level switch for liquids and is used in Tanks, vessels, and pipes.

Power/Communication

  20 ... 253V AC/DC, 2-wire
  10 ... 30V DC-PNP 3-wire

Ambient Temperature

  -40 °C ... 70 °C
  (-40 °F ... 158 °F)

Process Temperature

  -40 °C ... 150 °C
  (-40 °F ... 158 °F)

Process Absolute Pressure/Maximum Overpressure Limits

Vacuum ... 40 bar
(Vacuum ... 580 psi)

Minimum Measured Medium Density

>>0.7 g/cm³
(>0.5 g/cm³ optional)

Contact Medium Components

316L

Process Connections

Threads:
G1/2, G3/4, G1, MNPT1/2, MNPT3/4, MNPT1, R1/2, R3/4, R1

Outputs

AC/DC, DC-PNP

Certificates and Authentications

CSA C/US

Safety approvals

Overfill

Design approvals

  EN 10204-3.1

Marine approval

  ABS/ LR/ BV/ DNV

Optional

  Adjustment switching delay
  Cleaned from oil+grease,
  PWIS free


Product Applications

Liquiphant FTL31 limit switches are used for liquid limit detection in tanks, containers, and pipelines.

They also provide overflow protection or pump dry-run protection in cleaning and filtration systems, as well as coolant tanks and lubricant tanks.

They are an ideal replacement for float switches or conductivity, capacitive, and optical sensor products.

Liquiphant FTL31 can be used in situations where conductivity, adhesion, disturbance, flow conditions, or bubbles render other measurement principles unsuitable.

The maximum process temperature for Liquiphant FTL31 is:

  • 100 °C (212 °F)

  • 150 °C (302 °F)

Do not use in hazardous areas.

In hygienic applications, Liquiphant FTL33 is recommended.


Instrument images are for reference only. In case of discrepancies, please refer to the text description. Products are supplied according to the model description. Please confirm the technical information before ordering.



Technical Specifications

Specification Value
Brand Endershaus
Category Tuning Fork Level Switch
Output Method AC/DC, DC-PNP
Process Connection G1/2
Probe Length 38mm
Process Temperature (°C) 100
Operating Power Supply Voltage (V) DC 24V
Share Article
Brand Name: Endress+Hauser Certification: ISO9001,CE
Place of Origin: China Condition: New
Warranty: 1 years Customized design: available
What are your strengths?

Ans. Lehiy specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3–7 days. Customized or rare models may take 10–30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions
Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco_logo
SFI-Wackerlogo
basf
16102F00621512
TheLindeGroup
hitachi
foxconn_logo
fusheng