E+H electrode CPS11D-7BA21 digital pH electrode
LEHIY item code: LH-0001
Quick buying check
This page helps you check E+H electrode CPS11D-7BA21 digital pH electrode before you ask for a quote.
Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.
LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.
Original German E+H electrode CPS11D-7BA21 digital pH, electrode also known as an E+H electrode probe, is currently in stock. The CPS11D series E+H probes are widely used in wastewater treatment equipment.
However, E+H electrodes are consumables, and customers are advised to keep an appropriate stock for replacement every six months.
The German E+H analog or Memosens digital electrodes are suitable for standard applications in process and environmental fields, featuring an anti-fouling PTFE diaphragm and an optional built-in temperature sensor. They are energy-efficient electrodes used in process and environmental engineering.
Reliable measurements can be performed even in high-concentration alkaline solutions or in hazardous areas. The low-maintenance and long-life design reduces operating costs for the E+H electrode CPS11D-7BA21.
Introduction to the German E+H Electrode pH Digital Electrode CPS11D-7BA21 Series: SPK: CAE [7] Type: Basic [BA] Application Range: 1-14pH, 0...135℃, 13 bar [2] Measuring Rod Length: 120mm [1] Certification: Non-explosion-proof German E+H Electrode CPS11D-7BA21 Incoming Product Photos:
I. E+H Industry Applications of the CPS11D-7BA21 German E+H Digital pH Electrode:
- Beverages;
- Water Treatment;
- Drinking Water;
- Cooling Water;
- Well Water;
- Incineration Plants;
- Food Industry;
- Plastics & Chemicals;
- Chemical Processes;
- Pulp and Paper Industry;
- Power Plants (eg, desulfurization units);
- Long-term monitoring and limit value monitoring under stable process conditions;
- Certified by ATEX, FM, and CSA, suitable for use in hazardous areas. Advantages of the CPS11D-7BA21 German E+H Digital pH Electrode:
- Robust electrode structure with a ring-shaped PTFE diaphragm, requiring minimal maintenance;
- Application process pressure up to 16 bar (232 psi);
- Process glass suitable for measuring high-concentration alkali solutions;
- Built-in Pt 100 or Pt 1000 temperature sensor with effective temperature compensation (optional).
- Biocompatibility certified
- Sterilizable
- Dual-chamber system with metal leads and long toxicity diffusion path, resulting in a long electrode lifespan
- Anti-toxic reference ion trap (optional, only applicable to CPS11D)
III. E+H pH Electrode CPS11D-7BA21 Digital Electrode Memosens Technology Advantages
- Digital data transmission ensures data security
- Stores sensor characteristic parameters, simplifying operation
- Non-contact induction signal transmission ensures high process safety
- Records sensor load parameters in the sensor, enabling pre-maintenance Original German E+H electrode CPS11D-7BA21 digital pH electrode
IV.
E+H pH Electrode CPS11D Technical Parameters Input Measurement Variable pH value Temperature Measurement Range AA type electrode (suitable for water/wastewater measurement): pH: 1...12 pH Temperature: -15...80℃ (5...176 F) BA type electrode (suitable for process measurement, sterilizable): pH: 0...14 pH Temperature: 0...135 ℃.
(32...275 F) Temperature: ° Caution: Please pay attention to the process operating conditions.
Environmental conditions: Ambient temperature: Caution: There is a risk of frost damage. Do not use the electrodes when the temperature is below -15°C.
Storage temperature 0...50°C Protection rating IP 68: TOP68 connector, high-temperature sterilization temperature up to 135℃ Test conditions: 1m water column, 50℃, 168 h IP 68: Memosens connector Test conditions: 10m water column, 25℃, 45 days Process conditions Process temperature AA type: -15...80℃ BA type: 0...135℃.
Process pressure 0...6 bar (0...87 psi) / 16 bar (232 psi) (Applicable to CPS11-xBAxESA, in-stock E+H electrodes CPS11D-7BAxx CPS11D-7BTxx) Conductivity min.
50μS/cm Process connection Pg 13.5 Certificates and certifications Explosion-proof certification (Ex) CPS11 (TOP68) ATEX II 1G EEx ia IIC T3/T4/T6 FM Cl. I Div.
- Compatible with Liquiline M CM42 and Mycom S CPM153 transmitters. CPS11D ATEX II 1G EEx ia IIC T3/T4/T6 FM/CSA Cl. I Div.
- Compatible with Liquiline M CM42 and Mycom S CPM153 transmitters. Note! The connector of the explosion-proof (Ex) type Memosens digital electrode has an orange ring. TUV certified TOP68 connectors: withstand pressure up to 16 bar, with at least three times overpressure protection. Memosens connectors: withstand pressure up to 16 bar, with at least three times overpressure protection. CPS11D electromagnetic compatibility (EMC) interference emission and immunity meet EN 61326: 1997 / A1: 1998 standards. Specific models in the CPS11D series of E+H electrodes: CPS11D-7AA21 and CPS11D-7BA21. Large quantities are currently in stock;
- bulk orders are possible*. Business inquiries are welcome! CPS11D-7BA2G, CPS11D-7AA2G, CPS11D-7BT2G, CPS11D-7BT21.
Plain language sourcing guide for E+H electrode CPS11D-7BA21 digital pH electrode
Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.
Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.
Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.
If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.
Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.
Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.
Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.
Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.
For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.
For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.
For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.
| Brand Name: | Endress+Hauser | Certification: | ISO9001, CE |
|---|---|---|---|
| Place of Origin: | China | Condition: | New |
| Warranty: | 1 year | Customized sourcing: | available |
What are your strengths?
Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.
What is your estimated delivery time?
Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.
What are your primary product offerings?
Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.
How can I get in touch with you?
Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.
What are your payment terms?
Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.
Feel free to Ask questions
E+H electrode CPS11D-7BA21 digital pH electrode
Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.
For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.
Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.
Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.
- Confirm the complete model number and any suffix printed on the nameplate.
- Share quantity, destination country, preferred shipping method, and target delivery date.
- Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
- Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.
Useful details for a faster quote
- Complete model and part number
- Required quantity and target delivery date
- Nameplate photos, drawings, or old purchase records
- Voltage, signal range, dimensions, or accessory needs
Model matching
We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.
Quality and delivery
Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.
Stock alternatives
For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.
E+H electrode CPS11D-7BA21 digital pH electrode verification notes
Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.
LEHIY reviews product name, part number, series, label information, and application requirements before shipment.
If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.
For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.
Trusted partners
We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.