E+H pure water pH electrode, old: CPS11D-7AS21, new: CPS11E-AA7AAS2
Installation Conditions
Installation Guide
Do not invert the electrode during installation. The tilt angle should be at least 15° to the horizontal, as a more horizontal tilt angle will create an air bubble layer in the glass hemisphere. This will reduce the humidity of the internal electrode pH membrane.
Caution!
Before installing the electrode, ensure that the threaded connections of the electrode components are clean and secure.
Manually tighten the electrode (3 Nm)! (This value is only applicable to the installation of the Endress+Hauser component)
Please follow the installation instructions in the user manual to install the components.
The minimum installation angle of the electrode must be 15° to the horizontal.
Product Features
Advantages
Uses a large-area PTFE annular diaphragm to ensure electrode durability
Suitable for biochemical reaction measurements
Usable at 6 bar pressure
Long service life
Steam sterilizable
Usable in highly alkaline process glass
Optional built-in Pt100 or T1000 temperature sensor for accurate temperature compensation
TOP68 connector ensures reliable transmission of measured values
Further advantages based on Memosens technology
Maximum process safety through non-contact inductive transmission
Secure Digital Data Transmission
Special Sensor Data Storage Function for Easy Operation
Sensor Storage of Characteristic Parameters for Pre-Maintenance of Instruments
Technical Parameters Specifications
Input
| Measured Variables | pH Value Temperature |
Measurement Range
| Electrode Type |
Applicable Scope |
Measurement Range |
| AA Type Electrode | Water/Wastewater Measurement | 0...12 pH, -15...80℃ |
| BA Type Electrode | Process Application, Steam Sterilization | 0...14 pH, 0...135℃ |
| FA Type Electrode | Hydrofluoride at 1g/L Concentration | 0...10 pH, 0...70℃ |
| AS Type Electrode | Pure Water Measurement | 1...12 pH, -15...80℃, 6bar, with Salt Ring |
| BT Type Electrode | Measurement in Complex and Harsh Media | 0...14pH, 0...135℃, 16bar, with ion trap, highly resistant to poisoning |
Please note the process operating conditions!
Environmental Conditions
| Ambient Temperature | Caution: Frost can damage the electrodes. Do not use the electrodes below -15°C. |
| Storage Temperature | 0...50°C |
| Protection Rating | IP 67: GSA connector with enclosed joint IP 68: TOP68 connector, temperature resistant up to 135°C (1m/3.28ft water column, 50°C, 168h) IP 68: Memosens connector (10m/32.81ft water column, 25°C, 45 days, 1mK l) |
Process Conditions
| Process Temperature |
|
| Process Pressure | 0...6bar |
| Pressure-Temperature-Load Chart | |
| Conductivity | Minimum 50 μS/cm (except AS type) |
| pH range |
|
| Temperature sensor | CPS11: Pt100 Pt1000 CPS11D: NTC |
| CPS11 Connector | CPS11: ESA: Threaded connector Pg13.5, TOP68 for electrodes with or without temperature sensors 16 bar triple overvoltage safety, explosion-proof GSA: Threaded connector Pg13.5 for electrodes without temperature sensors CPS11D:Memosens connector for digital, non-contact data transmission |
| Reference System | Ag/AgCl metal lead with 3mol KCl modified gel, AgCl-free |
Note: The electrode glass membrane must always be kept moist and must not be exposed to air or water.
Selection Guide
CPS11 Product Selection Table
CPS11D Product Selection Table
Product Dimensions
Mechanical Structure
CPS11 Design and Dimensions
CPS11 with GSA connector
CPS11 with ESA connector, built-in temperature sensor
CPS11D Design and Dimensions
CPS11D with Memo sens connector, built-in temperature sensor
Product Applications
Applications
Process Technology and Monitoring
Papermaking
Petrochemicals
Power plants (e.g., desulfurization units)
Smelting
Food industry
Brewing plants
Water treatment
Drinking water
Cooling water
Influent water
Technical Specifications
| Weight | ||
| Material | Electrode Main Rod pH Diaphragm Glass Metal Leads Diaphragm Process Glass Types A, B, and F Ag/AgCl Annular Teflon Diaphragm, Steam Sterilized |
|
| Process Connection | Pg13.5 | |
| Specification | Value |
|---|---|
| Brand | Endeshaus E+H |
| Category | PH Sensor |
| Wire Length (m) | None |
| Accuracy | ±0.01 |
| Brand Name: | Endress+Hauser | Certification: | ISO9001,CE |
|---|---|---|---|
| Place of Origin: | China | Condition: | New |
| Warranty: | 1 years | Customized design: | available |
What are your strengths?
Ans. Lehiy specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.
What is your estimated delivery time?
Ans. Most items ship within 3–7 days. Customized or rare models may take 10–30 working days.
What are your primary product offerings?
Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.
How can I get in touch with you?
Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.
What are your payment terms?
Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.
Feel free to Ask questions
Trusted partners
We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.