E+H PH composite electrode, CPS11-2AS2ESA
LEHIY item code: LH-0020
Quick buying check
This page helps you check E+H PH composite electrode, CPS11-2AS2ESA before you ask for a quote.
Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.
LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.
Installation Conditions
Installation Guide
Do not invert the electrode during installation. The tilt angle should be at least 15° to the horizontal, as a more horizontal tilt angle will create an air bubble layer in the glass hemisphere. This will reduce the humidity of the internal electrode pH membrane.
Caution!
Before installing the electrode, ensure that the threaded connections of the electrode components are clean and secure.
Manually tighten the electrode (3 Nm)! (This value is only applicable to the installation of the Endress+Hauser component)
Please follow the installation instructions in the user manual to install the components.
The minimum installation angle of the electrode must be 15° to the horizontal.
Product Features
Advantages
Uses a large-area PTFE annular diaphragm to ensure electrode durability
Suitable for biochemical reaction measurements
Usable at 6 bar pressure
Long service life
Steam sterilizable
Usable in highly alkaline process glass
Optional built-in Pt100 or T1000 temperature sensor for accurate temperature compensation
TOP68 connector ensures reliable transmission of measured values
Further advantages based on Memosens technology
Maximum process safety through non-contact inductive transmission
Secure Digital Data Transmission
Special Sensor Data Storage Function for Easy Operation
Sensor Storage of Characteristic Parameters for Pre-Maintenance of Instruments
Technical Parameters Specifications
Input
| Measured Variables | pH Value Temperature |
Measurement Range
| Electrode Type | Applicable Scope | Measurement Range |
| AA Type Electrode | Water/Wastewater Measurement | 0...12 pH, -15...80℃ |
| BA Type Electrode | Process Application, Steam Sterilization | 0...14 pH, 0...135℃ |
| FA Type Electrode | Hydrofluoride at 1g/L Concentration | 0...10 pH, 0...70℃ |
| AS Type Electrode | Pure Water Measurement | 1...12 pH, -15...80℃, 6bar, with Salt Ring |
| BT Type Electrode | Measurement in Complex and Harsh Media | 0...14pH, 0...135℃, 16bar, with ion trap, highly resistant to poisoning |
Please note the process operating conditions!
Environmental Conditions
| Ambient Temperature | Caution: Frost can damage the electrodes. Do not use the electrodes below -15°C. |
| Storage Temperature | 0...50°C |
| Protection Rating | IP 67: GSA connector with enclosed joint IP 68: TOP68 connector, temperature resistant up to 135°C (1m/3.28ft water column, 50°C, 168h) IP 68: Memosens connector (10m/32.81ft water column, 25°C, 45 days, 1mK l) |
Process Conditions
| Process Temperature |
|
| Process Pressure | 0...6bar |
| Pressure-Temperature-Load Chart | |
| Conductivity | Minimum 50 μS/cm (except AS type) |
| pH range |
|
| Temperature sensor | CPS11: Pt100 Pt1000 CPS11D: NTC |
| CPS11 Connector | CPS11: ESA: Threaded connector Pg13.5, TOP68 for electrodes with or without temperature sensors 16 bar triple overvoltage safety, explosion-proof GSA: Threaded connector Pg13.5 for electrodes without temperature sensors CPS11D:Memosens connector for digital, non-contact data transmission |
| Reference System | Ag/AgCl metal lead with 3mol KCl modified gel, AgCl-free |
Note: The electrode glass membrane must always be kept moist and must not be exposed to air or water.
Selection Guide
CPS11 Product Selection Table
CPS11D Product Selection Table
Product Dimensions
Mechanical Structure
CPS11 Design and Dimensions
CPS11 with GSA connector
CPS11 with ESA connector, built-in temperature sensor
CPS11D Design and Dimensions
CPS11D with Memo sens connector, built-in temperature sensor
Product Applications
Applications
Process Technology and Monitoring
Papermaking
Petrochemicals
Power plants (e.g., desulfurization units)
Smelting
Food industry
Brewing plants
Water treatment
Drinking water
Cooling water
Influent water
Technical Specifications
| Weight | |
| Material | Electrode Main Rod pH Diaphragm Glass Metal Leads Diaphragm Process Glass Types A, B, and F Ag/AgCl Annular Teflon Diaphragm, Steam Sterilized |
| Process Connection | Pg13.5 |
| Specification | Value |
|---|---|
| Brand | Endeshaus E+H |
| Category | PH Sensor |
| Wire Length (m) | None |
| Accuracy | ±0.01 |
Plain language sourcing guide for E+H PH composite electrode, CPS11-2AS2ESA
Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.
Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.
Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.
If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.
Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.
Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.
Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.
Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.
For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.
For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.
For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.
| Brand Name: | Endress+Hauser | Certification: | ISO9001, CE |
|---|---|---|---|
| Place of Origin: | China | Condition: | New |
| Warranty: | 1 year | Customized sourcing: | available |
What are your strengths?
Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.
What is your estimated delivery time?
Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.
What are your primary product offerings?
Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.
How can I get in touch with you?
Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.
What are your payment terms?
Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.
Feel free to Ask questions
E+H PH composite electrode, CPS11-2AS2ESA
Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.
For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.
Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.
Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.
- Confirm the complete model number and any suffix printed on the nameplate.
- Share quantity, destination country, preferred shipping method, and target delivery date.
- Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
- Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.
Useful details for a faster quote
- Complete model and part number
- Required quantity and target delivery date
- Nameplate photos, drawings, or old purchase records
- Voltage, signal range, dimensions, or accessory needs
Model matching
We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.
Quality and delivery
Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.
Stock alternatives
For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.
E+H PH composite electrode, CPS11-2AS2ESA verification notes
Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.
LEHIY reviews product name, part number, series, label information, and application requirements before shipment.
If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.
For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.
More In This Category
Trusted partners
We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.