-Automatic Reset min Depends on Tripping Current Magnitude and Characteristics -Manual Reset min Depends on Tripping Current Magnitude and Characteristics Characteristics Status Display √ Test Function √ Temperature Compensation ℃ 70 80 Permissible Rated Current -Control Cabinet Internal Temperature 60℃ % 94 100 -Control Cabinet Internal Temperature 70℃ % 82.

87 Adapter Terminals Coil Adapter Terminal Not Required Auxiliary Contact Adapter Terminal Not Required Protection Rating: Complies with IEC 60529 standard IP00 (open), IP20 (with terminal cover) Finger Touch Protection: Complies with IEC 61140 standard Finger Touch Safety (with terminal cover) Shock Resistance: Complies with IEC 60068-2-27 Standard.

g/ms 8/10 Air Humidity % 90 100 Altitude m Up to 2000m.

For altitudes above 2000m, please contact Siemens technical support hotline.: -Automatic Reset.

Category: Thermal Overload Relay

Rated Operating Voltage U e: V

Quick buying check

This page helps you check SIEMENS 3RU5 thermal overload relay, 3RU5146-4FB0 28-40A 3RU51464FB0 before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

Technical Specifications

280…400 to 350…500 Ω Normally closed contact (NC), AC-14/AC-15, rated current Ie under rated operating voltage Ue
3RU5-Overload Relay
Type3RU51 563RU51 663RU51 76
SpecificationsS6S10S12
Width106(1))</sup>mm145mm145mm
General Technical Data
Trip TypeOverload and Phase Loss
Trip ClassCLASS10
Reset and Recovery
Trip Reset TypeManual and Automatic Reset
-Automatic ResetminDepends on Tripping Current Magnitude and Characteristics
-Manual ResetminDepends on Tripping Current Magnitude and Characteristics
Characteristics
Status Display
Test Function
Temperature Compensation7080
Permissible Rated Current
-Control Cabinet Internal Temperature 60℃%94100
-Control Cabinet Internal Temperature 70℃%8287
Adapter Terminals
Coil Adapter TerminalNot Required
Auxiliary Contact Adapter TerminalNot Required
Protection Rating: Complies with IEC 60529 standardIP00 (open), IP20 (with terminal cover)
Finger Touch Protection: Complies with IEC 61140 standardFinger Touch Safety (with terminal cover)
Shock Resistance: Complies with IEC 60068-2-27 Standardg/ms8/10
Air Humidity90100
AltitudemUp to 2000m. For altitudes above 2000m, please contact Siemens technical support hotline.
Installation MethodIndependent Installation
Main Circuit
Rated Insulation Voltage U<sub>i</sub> (Pollution Degree 3)V1000
Rated Impulse Withstand Voltage U<sub>imp</sub>kV8
Rated Operating Voltage U<sub>e</sub>V1000
Current Type
DCAvailable (2)</sup>Unavailable
ACAvailable, frequency up to 400Hz
Current RangeA55…80 to 170…205140…200 to 220…320
Maximum power consumption per thermal overload relayW242136
Insulation between main and auxiliary circuits conforms to IEC60947-1 standardV1000
1) Except for 3RU5156-3NB1 2) Requires three-pole series connection
Cross-sectional area of ​​main circuit conductor
Screw Terminal Block
Terminal ScrewM8 (Hexagonal Outer Head)<sup>2)</sup>M10 (Hexagonal Outer Head)M10 (Hexagonal Outer Head)
Tightening TorqueNm10…1414…2414…24
Conductor Cross-sectional Area (Maximum...Minimum)
1 or 2 wires
Fine multi-strand wire with prefabricated terminalsmm<sup>2</sup>2x(16…95)2x(35…150) Max.1x2402x(95…150) Max.1x240
AWG wire, solid or multi-strand wireAWG1/0…250kcmil2/0…500kcmil2/0…500kcmil
Ribbon Cable/Busbarmm2x20x32x25x62x25x6
Auxiliary Circuit
Number of Normally Open Contacts1
Number of Normally Closed Contacts1
i</sub> (pollution degree 3) V 690 Rated impulse withstand voltage U<sub>imp</sub> kV 8 9 Breakthrough capacity of auxiliary contactsAuxiliary contact assignment
Breakthrough capacity of auxiliary contacts
24VA4
120VA4
125VA4
230VA
400VA2
600VA0.75
690VA0.75
NO Normally open contact, AC-14/AC-15, rated operating current Ie under rated operating voltage U<sub>e</sub>
24VA3
120VA3
125VA3
230VA2
400VA
600VA0.75
690VA0.75
NC normally closed contact and NO normally open contact, DC-13, rated operating current Ie under rated operating voltage U<sub>e</sub>
24VA1
A6
Contact ReliabilitySuitable for solid-state circuits, minimum current handling 5mA (17V)
Safety isolation between main and auxiliary circuits, compliant with IEC60947-1 standardV≥400
Auxiliary circuit conductor cross-sectional area
Screw terminal block
Terminal screwM3, No. 2 crosshead screwdriver
Tightening torqueNm0.8…1.2
Conductor cross-sectional area
1 or 2 wires
Solid wiremm<sup>2</sup>2x(0.5…1.5)1), 2x(0.75…2.5)1)
mm<sup>2</sup>2x(0.5…1.5)1), 2x(0.75…2.5)1)
AWG wire, solid or multi-strand wireAWG2x(20…16)1), 2x(18…14)1)
1) If two wires with different cross-sectional areas need to be connected to one terminal block, ensure that the cross-sectional areas of both wires are within the required range.
2) For the 3RU5156-3NB1 product, M8 and M10 wiring screws are required
- Temperature inside the control cabinet: 70℃ % 87 ... Protection Rating: Complies with IEC 60529 standard 3) </sup>
3RU5-Overload Relay
Type3RU51 363RU51 46
SpecificationsS2S3
Width55mm70mm
General Technical Data
Trip TypeOverload and Phase Loss
Trip Class: Compliant with IEC 60947-4-1 StandardCLASS10
Reset and Recovery
Trip Reset TypeManual and Automatic Reset
Reset Time
Reset Time
-Automatic ResetminDepends on Tripping Current Magnitude and Characteristics
-Manual ResetminDepends on Tripping Current Magnitude and Characteristics
Characteristics
Status Display
Test Function
IP20IP20 (1)
Finger Touch Protection: Complies with IEC 61140 standardFinger Touch Safety
Shock Resistance: Complies with IEC 60068-2-27 standardg/ms8/10
Air Humidity%100
AltitudemUp to 2000. For altitudes above 2000 m, please contact Siemens technical support.
Installation MethodPlug-in with contactor or use with independent mounting bracket for independent installation.
1) Terminal grid protection rating IP00
2) Auxiliary contacts 95/96 and 97/98 shock resistance: 8g/11ms
3) Can be used for screw fixing or 35 mm standard DIN rail mounting.
Main Circuit
Rated Insulation Voltage U<sub>i</sub> (Pollution Degree 3)V6901000
Rated Impulse Withstand Voltage U<sub>imp</sub>kV68
Rated Operating Voltage U<sub>e</sub>V6901000
Current Type
DCAvailable
ACAvailable, frequency up to 400 Hz
Current RangeA5.5...8 to 40...5018...25 to 80...100
Maximum Power Consumption per Thermal Overload RelayW6...910...16.5
Safety insulation between main circuit and auxiliary circuit (compliant with IEC 60947-1 standard)V≥ 440
Auxiliary circuit
Number of normally open contacts1
Number of normally closed contacts1
Auxiliary contact allocation1 NO Provides "trip" signal
1 NC for disconnecting the contactor
Break-off capacity of auxiliary contacts
·NC normally closed contact, AC-14/AC-15, rated current Ie under rated operating voltage U<sub>e</sub>:
-24VA4
-120VA4
-125VA4
-230VA3
-400VA2
-600VA0.75
-690VA
·NO normally open contact, AC-14/AC-15, rated current Ie under rated operating voltage U<sub>e</sub>:
-24VA3
-120VA3
-125VA3
-230VA2
-400VA1
-600VA0.75
-690VA0.75
-24VA1
-60VAFor details, please consult Siemens technical support hotline
-110VA0.22
-125VA0.22
-220VA0.11
·Conventional Heating Current IthA6
·Contact ReliabilitySuitable for solid-state circuits, minimum on-state current 5 mA (at 17 V).
Safety isolation between main circuit and auxiliary circuit (compliant with IEC 60947-1 standard)A≥ 440
Cross-sectional area of ​​auxiliary circuit conductor
Screw terminal block
Terminal screwM3, No. 2 cross-section screwdriver
Tightening torqueNm0.8 ... 1.2
Conductor cross-sectional area (maximum...minimum)
Can connect 1 or 2 wires
·Solid wiremm<sup>2</sup>2×(0.5 ... 1.5) <sup>1)</sup> ,2×(0.75 ... 2.5) <sup>1)</sup>
·Fine multi-strand wire with prefabricated terminal blocks (DIN 46228 T<sup> 1)</sup>mm<sup>2</sup>2×(0.5 ... 1.5) <sup>1)</sup> ,2×(0.75 ... 2.5) <sup>1)</sup>
·AWG conductor, solid or multi-strand conductor2×(20 ... 16) <sup>1)</sup> ,2×(18 ... 14) <sup>1)</sup>
1) If two conductors with different cross-sectional areas need to be connected to one terminal block, ensure that the cross-sectional areas of both conductors are within the required range.


Product Applications

  • RU61/3RU51 thermal overload relays can be used for the protection of three-phase or single-phase AC or DC motors

  • If using the 3RU61/3RU51 thermal overload relay to protect single-phase AC or DC loads, the three poles must be connected in series

Technical Specifications

<t r>
SpecificationValue
BrandSIEMENS
CategoryThermal Overload Relay
Series3RU
Setting Current Range (A)28-40
Installation MethodPlug-in Type
Applicable Contactors3RT50

Plain language sourcing guide for SIEMENS 3RU5 thermal overload relay, 3RU5146-4FB0 28-40A 3RU51464FB0

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:SiemensCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

SIEMENS 3RU5 thermal overload relay, 3RU5146-4FB0 28-40A 3RU51464FB0

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

SIEMENS 3RU5 thermal overload relay, 3RU5146-4FB0 28-40A 3RU51464FB0 verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo
fusheng logo