SIEMENS 3RV5 Motor Protection Circuit Breaker, 3RV5031-4DA10 11KW 18-25A, 3RV50314DA10

LEHIY item code: LH-0231

Rated Operating Voltage Ue: V

Category: Motor Protection Circuit Breakers

Undervoltage release: √ √

Quick buying check

This page helps you check SIEMENS 3RV5 Motor Protection Circuit Breaker, 3RV5031-4DA10 11KW 18-25A, 3RV50314DA10 before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

Technical Specifications

Model

3RV60/3RV50

3RV63/3RV53

3RV64/3RV54

SIRIUS (Domestic) 3RV6/3RV5 Circuit Breaker, Maximum 100A

Application Category

System Protection (Line Protection)

√1)

-

-

Motor Protection

-

-

Starting Combination Short Circuit Protection

-

-

Transformer Protection

-

-

Size Specifications

S00,S0,S2,S3

S00,S0,S2,S3

S00,S0,S2,S3

S00,S0,S2

Rated Current/n

Specification S00

A

To 16

To 16

To 16

Specification S0

A

To 40

To 40

To 25

Specification S2

A

To 50

To 50

To 40

Specification S3

A

To 100

To 100

-

Rated Operating Voltage Ue

V

690 (AC) 2)

690 (AC) 2)

690 (AC) 2)

According to IEC standards

Rated frequency

Hz

50/60

50/60

50/60

Trip Class

CLASS 10

-

CLASS 10

Thermal Overload Trip Current Setting Range

A

0.11...0.16 to 80...100

None 3)

0.11...0.16 to 28...40

Short-circuit tripping current

13 times rated current

13 times rated current

20 times rated current

Rated short-circuit breaking capacity/cu

kA

20/50/55/100

20/50/55/100

50/55/100

AC 400V

Common Attachments

Applicable Specifications

S00             S0

  S2           S3

S00     S0

S2       S3

S00      S0

Auxiliary contacts

√                  √

  √             √

√          √

√         √

√           √

Fault signaling contact

√                  √

  √             √

√          √ 

√         √

√           √

Undervoltage release

√                  √

  √             √

√          √

√         √

√           √

Shunt release

√                   √

  √             √

√          √

√         √

√           √

Three-phase insulated bus system

√                   √

  √              -

√          √

√          -

√           √

Door coupling rotary operating mechanism

√                   √

  √             √

√          √

√          √

√           √

Connection module with contactor

√                   √

  √             √

√          √

√          √

√           √

Fixed mounting hardware

√                   √

  -               -

√          √

-           -

√         √

√ This function is available or this attachment can be used

1) Applicable to three-phase symmetrical loads.

- This function is not available or this attachment cannot be used

2) AC 500V when using the plastic protective cover attachment.

3) For motor overload protection, a suitable overload relay must be used.

Motor Protection

Trip Class CLASS 10, Screw Terminal, with or without Auxiliary Contacts

3RV60 11-..A1.

3RV60 21-4.A1.

3RV50 31-4.A10

3RV50 41-4.A10

Rated Current/n

Applicable to Three-Phase AC Motors 1) Power P

Thermal Overload Trip Unit Setting Current Range

Short Circuit Trip Current

Ultimate Short Circuit Breaking Capacity under AC 400V Conditions/cu

No Auxiliary Contacts

With Lateral Mounting 1NO+1NC Auxiliary Contacts

A

kW

A

A

kA

Order Number

Order Number

S00 Specification

0.16

0.04

0.11...0.16

2.1

100

3RV60 11-0AA10

3RV60 11-0AA15

0.2

0.06

0.14...0.2

2.6

100

3RV60 11-0BA10

3RV60 11-0BA15

0.25

0.06

0.18...0.25

3.3

100

3RV60 11-0CA10

3RV60 11-0CA15

0.32

0.09

0.22...0.32

4.2

100

3RV60 11-0DA10

3RV60 11-0DA15

0.4

0.09

0.28...0.4

5.2

100

3RV60 11-0EA10

3RV60 11-0EA15

0.5

0.12

0.35...0.5

6.5

100

3RV60 11-0FA10

3RV60 11-0FA15

0.63

0.18

0.45...0.63

8.2

100

3RV60 11-0GA10

3RV60 11-0GA15

0.8

0.18

0.55...0.8

10

100

3RV60 11-0HA10

3RV60 11-0HA15

1

0.25

0.7...1

13

100

3RV60 11-0JA10

3RV60 11-0JA15

1.25

0.37

0.9...1.25

16

100

3RV60 11-0KA10

3RV60 11-0KA15

1.6

0.55

1.1...1.6

21

100

3RV60 11-1AA10

3RV60 11-1AA15

2

0.75

1.4...2

26

100

3RV60 11-1BA10

3RV60 11-1BA15

2.5

0.75

1.8...2.5

33

100

3RV60 11-1CA10

3RV60 11-1CA15

3.2

1.1

2.2...3.2

42

100

3RV60 11-1DA10

3RV60 11-1DA15

4

1.5

2.8...4

52

100

3RV60 11-1EA10

3RV60 11-1EA15

5

1.5

3.5...5

65

100

3RV60 11-1FA10

3RV60 11-1FA15

6.3

2.2

4.5...6.3

82

100

3RV60 11-1GA10

3RV60 11-1GA15

8

3

5.5...8

104

100

3RV60 11-1HA10

3RV60 11-1HA15

10

4

7...10

130

100

3RV60 11-1JA10

3RV60 11-1JA15

12.5

5.5

9...12.5

163

100

3RV60 11-1KA10

3RV60 11-1KA15

16

7.5

11...16

208

50

3RV60 11-4AA10

3RV60 11-4AA15

S0 specifications

16

7.5

11...16

208

55

3RV60 21-4AA10

3RV60 21-4AA15

20

7.5

14...20

260

55

3RV60 21-4BA10

3RV60 21-4BA15

22

11

17...22

286

55

3RV60 21-4CA10

3RV60 21-4CA15

25

11

20...25

325

55

3RV60 21-4DA10

3RV60 21-4DA15

28

15

23...28

364

55

3RV60 21-4NA10

3RV60 21-4NA15

32

15

27...32

400

55

3RV60 21-4EA10

3RV60 21-4EA15

36

18.5

30...36

432

20

3RV60 21-4PA10

3RV60 21-4PA15

40

18.5

34...40

480

20

3RV60 21-4FA10

3RV60 21-4FA15

S2 Specifications

16

7.5

11...16

208

50

3RV50 31-4AA10

-

20

7.5

14...20

260

50

3RV50 31-4BA10

-

25

11

18...25

325

50

3RV50 31-4DA10

-

32

15

22...32

416

50

3RV50 31-4EA10

-

40

18.5

28...40

520

50

3RV50 31-4FA10

-

45

22

36...45

585

50

3RV50 31-4GA10

-

50

22

40...50

650

50

3RV50 31-4HA10

-

S3 Specifications

40

18.5

28...40

520

50

3RV50 41-4FA10

-

50

22

36...50

690

50

3RV50 41-4HA10

-

63

30

45...63

819

50

3RV50 41-4JA10

-

75

37

57...75

975

50

3RV50 41-4KA10

-

90

45

70...90

1170

50

3RV50 41-4LA10

-

100

45

80...100

1235

50

3RV50 41-4MA10

-

1) Data corresponding to a standard four-pole motor under AC 50Hz, 400V conditions. When selecting a model, the protection should be based on the following:

Notices

Preventing Accidental Tripping

  • Because the motor protection circuit breaker has a phase loss protection function, it is essential to ensure that current flows through all three phases during connection.

Short Circuit Protection

  • In the event of a short circuit, the short-circuit trip unit of the 3RV6/3RV5 circuit breaker can isolate the faulty load feeder from the power supply, thereby preventing further losses.

  • Most models of the 3RV6/3RV5 circuit breakers have a rated ultimate short-circuit breaking capacity of over 50 kA at AC 400 V, offering extremely high short-circuit protection reliability because such high short-circuit currents are rarely encountered. Motor Protection The tripping characteristics of the 3RV60/3RV50 motor protection circuit breakers are primarily designed for protecting three-phase induction motors. The rated current In for motor protection can be adjusted via the setting knob. The short-circuit tripping current is fixed at 13 times the rated current of the motor protection circuit breaker. This ensures that the motor will not trip due to a fault and will receive appropriate protection during startup. If a phase loss or overcurrent occurs due to a phase line fault, the phase loss protection of the motor protection circuit breaker guarantees timely tripping. The design tripping class of the motor protection circuit breaker equipped with a thermal overload trip unit is CLASS 10.

System Protection

  • The 3RV60/3RV50 motor protection circuit breaker, used for motor protection, can also be used for system protection. To prevent premature tripping due to single-phase protection, the protected load must be a three-phase symmetrical load.

    If it is a single-phase load, the circuit must be connected in series.

Short Circuit Protection for Starting Combinations

  • The 3RV63/3RV53 circuit breaker, in combination with a contactor and overload relay, can be used for short circuit protection of starting combinations.

    Like the motor protection circuit breaker for motor protection, the 3RV63/3RV53 circuit breaker is also equipped with a short-circuit trip unit, whose trip value is fixed at 13 times the rated current of the circuit breaker, without an overload trip unit.

    In the event of an overload, the overload relay will trigger the contactor to open, while the circuit breaker remains closed.

    The circuit breaker will only trip when a short circuit occurs in the feeder. Since the circuit breaker used in the starting combination cannot protect the motor independently and cannot prevent overload, it must be used in conjunction with an overload relay. Transformer Protection
    • When protecting a control transformer on the power supply side, the instantaneous current generated when the transformer is switched on often causes the protection mechanism to trip erroneously.

      Therefore, the short-circuit trip value of the 3RV64/3RV54 circuit breaker used for transformer protection is fixed at 20 times the rated current value, thus it can be used to protect transformers with surge peak currents of 30 times the rated current on the power supply side.

      Control transformers with lower surge currents do not require this type of circuit breaker; the 3RV60/3RV50 motor protection circuit breaker used for motor protection can be used instead.

    Main Switch and Emergency Stop Switch

    • 3RV6/3RV5 circuit breakers have isolation functions conforming to IEC 60947-2 and can be used as main switches and emergency stop switches

Technical Specifications

SpecificationValue
BrandSIEMENS
CategoryMotor Protection Circuit Breakers
Series Columns3RV5
Thermal Overload Trip Unit Setting Current Range (A)18-25
Rated Ultimate Short Circuit Breaking Capacity (KA)50
Wiring MethodScrew Terminal Block

Plain language sourcing guide for SIEMENS 3RV5 Motor Protection Circuit Breaker, 3RV5031-4DA10 11KW 18-25A, 3RV50314DA10

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:SiemensCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

SIEMENS 3RV5 Motor Protection Circuit Breaker, 3RV5031-4DA10 11KW 18-25A, 3RV50314DA10

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

SIEMENS 3RV5 Motor Protection Circuit Breaker, 3RV5031-4DA10 11KW 18-25A, 3RV50314DA10 verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo
fusheng logo