Technical Specifications
Model | 3RV60/3RV50 | 3RV63/3RV53 | 3RV64/3RV54 | |||
SIRIUS (Domestic) 3RV6/3RV5 Circuit Breaker, Maximum 100A | ||||||
Application Category | ||||||
System Protection (Line Protection) | √1) | - | - | |||
Motor Protection | √ | - | - | |||
Starting Combination Short Circuit Protection | - | √ | - | |||
Transformer Protection | - | - | √ | |||
Size Specifications | S00,S0,S2,S3 | S00,S0,S2,S3 | S00,S0,S2,S3 | S00,S0,S2 | ||
Rated Current/n | ||||||
Specification S00 | A | To 16 | To 16 | To 16 | ||
Specification S0 | A | To 40 | To 40 | To 25 | ||
Specification S2 | A | To 50 | To 50 | To 40 | ||
Specification S3 | A | To 100 | To 100 | - | ||
Rated Operating Voltage Ue | V | 690 (AC) 2) | 690 (AC) 2) | 690 (AC) 2) | ||
According to IEC standards | ||||||
Rated frequency | Hz | 50/60 | 50/60 | 50/60 | ||
Trip Class | CLASS 10 | - | CLASS 10 | |||
Thermal Overload Trip Current Setting Range | A | 0.11...0.16 to 80...100 | None 3) | 0.11...0.16 to 28...40 | ||
Short-circuit tripping current | 13 times rated current | 13 times rated current | 20 times rated current | |||
Rated short-circuit breaking capacity/cu | kA | 20/50/55/100 | 20/50/55/100 | 50/55/100 | ||
AC 400V | ||||||
Common Attachments | ||||||
Applicable Specifications | S00 S0 | S2 S3 | S00 S0 | S2 S3 | S00 S0 | |
Auxiliary contacts | √ √ | √ √ | √ √ | √ √ | √ √ | |
Fault signaling contact | √ √ | √ √ | √ √ | √ √ | √ √ | |
Undervoltage release | √ √ | √ √ | √ √ | √ √ | √ √ | |
Shunt release | √ √ | √ √ | √ √ | √ √ | √ √ | |
Three-phase insulated bus system | √ √ | √ - | √ √ | √ - | √ √ | |
Door coupling rotary operating mechanism | √ √ | √ √ | √ √ | √ √ | √ √ | |
Connection module with contactor | √ √ | √ √ | √ √ | √ √ | √ √ | |
Fixed mounting hardware | √ √ | - - | √ √ | - - | √ √ | |
√ This function is available or this attachment can be used | 1) Applicable to three-phase symmetrical loads. | |||||
- This function is not available or this attachment cannot be used | 2) AC 500V when using the plastic protective cover attachment. | |||||
3) For motor overload protection, a suitable overload relay must be used. | ||||||
Motor Protection | ||||||
Trip Class CLASS 10, Screw Terminal, with or without Auxiliary Contacts | ||||||
3RV60 11-..A1. | 3RV60 21-4.A1. | 3RV50 31-4.A10 | 3RV50 41-4.A10 | |||
Rated Current/n | Applicable to Three-Phase AC Motors 1) Power P | Thermal Overload Trip Unit Setting Current Range | Short Circuit Trip Current | Ultimate Short Circuit Breaking Capacity under AC 400V Conditions/cu | No Auxiliary Contacts | With Lateral Mounting 1NO+1NC Auxiliary Contacts |
A | kW | A | A | kA | Order Number | Order Number |
S00 Specification | ||||||
0.16 | 0.04 | 0.11...0.16 | 2.1 | 100 | 3RV60 11-0AA10 | 3RV60 11-0AA15 |
0.2 | 0.06 | 0.14...0.2 | 2.6 | 100 | 3RV60 11-0BA10 | 3RV60 11-0BA15 |
0.25 | 0.06 | 0.18...0.25 | 3.3 | 100 | 3RV60 11-0CA10 | 3RV60 11-0CA15 |
0.32 | 0.09 | 0.22...0.32 | 4.2 | 100 | 3RV60 11-0DA10 | 3RV60 11-0DA15 |
0.4 | 0.09 | 0.28...0.4 | 5.2 | 100 | 3RV60 11-0EA10 | 3RV60 11-0EA15 |
0.5 | 0.12 | 0.35...0.5 | 6.5 | 100 | 3RV60 11-0FA10 | 3RV60 11-0FA15 |
0.63 | 0.18 | 0.45...0.63 | 8.2 | 100 | 3RV60 11-0GA10 | 3RV60 11-0GA15 |
0.8 | 0.18 | 0.55...0.8 | 10 | 100 | 3RV60 11-0HA10 | 3RV60 11-0HA15 |
1 | 0.25 | 0.7...1 | 13 | 100 | 3RV60 11-0JA10 | 3RV60 11-0JA15 |
1.25 | 0.37 | 0.9...1.25 | 16 | 100 | 3RV60 11-0KA10 | 3RV60 11-0KA15 |
1.6 | 0.55 | 1.1...1.6 | 21 | 100 | 3RV60 11-1AA10 | 3RV60 11-1AA15 |
2 | 0.75 | 1.4...2 | 26 | 100 | 3RV60 11-1BA10 | 3RV60 11-1BA15 |
2.5 | 0.75 | 1.8...2.5 | 33 | 100 | 3RV60 11-1CA10 | 3RV60 11-1CA15 |
3.2 | 1.1 | 2.2...3.2 | 42 | 100 | 3RV60 11-1DA10 | 3RV60 11-1DA15 |
4 | 1.5 | 2.8...4 | 52 | 100 | 3RV60 11-1EA10 | 3RV60 11-1EA15 |
5 | 1.5 | 3.5...5 | 65 | 100 | 3RV60 11-1FA10 | 3RV60 11-1FA15 |
6.3 | 2.2 | 4.5...6.3 | 82 | 100 | 3RV60 11-1GA10 | 3RV60 11-1GA15 |
8 | 3 | 5.5...8 | 104 | 100 | 3RV60 11-1HA10 | 3RV60 11-1HA15 |
10 | 4 | 7...10 | 130 | 100 | 3RV60 11-1JA10 | 3RV60 11-1JA15 |
12.5 | 5.5 | 9...12.5 | 163 | 100 | 3RV60 11-1KA10 | 3RV60 11-1KA15 |
16 | 7.5 | 11...16 | 208 | 50 | 3RV60 11-4AA10 | 3RV60 11-4AA15 |
S0 specifications | ||||||
16 | 7.5 | 11...16 | 208 | 55 | 3RV60 21-4AA10 | 3RV60 21-4AA15 |
20 | 7.5 | 14...20 | 260 | 55 | 3RV60 21-4BA10 | 3RV60 21-4BA15 |
22 | 11 | 17...22 | 286 | 55 | 3RV60 21-4CA10 | 3RV60 21-4CA15 |
25 | 11 | 20...25 | 325 | 55 | 3RV60 21-4DA10 | 3RV60 21-4DA15 |
28 | 15 | 23...28 | 364 | 55 | 3RV60 21-4NA10 | 3RV60 21-4NA15 |
32 | 15 | 27...32 | 400 | 55 | 3RV60 21-4EA10 | 3RV60 21-4EA15 |
36 | 18.5 | 30...36 | 432 | 20 | 3RV60 21-4PA10 | 3RV60 21-4PA15 |
40 | 18.5 | 34...40 | 480 | 20 | 3RV60 21-4FA10 | 3RV60 21-4FA15 |
S2 Specifications | ||||||
16 | 7.5 | 11...16 | 208 | 50 | 3RV50 31-4AA10 | - |
20 | 7.5 | 14...20 | 260 | 50 | 3RV50 31-4BA10 | - |
25 | 11 | 18...25 | 325 | 50 | 3RV50 31-4DA10 | - |
32 | 15 | 22...32 | 416 | 50 | 3RV50 31-4EA10 | - |
40 | 18.5 | 28...40 | 520 | 50 | 3RV50 31-4FA10 | - |
45 | 22 | 36...45 | 585 | 50 | 3RV50 31-4GA10 | - |
50 | 22 | 40...50 | 650 | 50 | 3RV50 31-4HA10 | - |
S3 Specifications | ||||||
40 | 18.5 | 28...40 | 520 | 50 | 3RV50 41-4FA10 | - |
50 | 22 | 36...50 | 690 | 50 | 3RV50 41-4HA10 | - |
63 | 30 | 45...63 | 819 | 50 | 3RV50 41-4JA10 | - |
75 | 37 | 57...75 | 975 | 50 | 3RV50 41-4KA10 | - |
90 | 45 | 70...90 | 1170 | 50 | 3RV50 41-4LA10 | - |
100 | 45 | 80...100 | 1235 | 50 | 3RV50 41-4MA10 | - |
1) Data corresponding to a standard four-pole motor under AC 50Hz, 400V conditions. When selecting a model, the protection should be based on the following: |
Notices
Preventing Accidental Tripping
Short Circuit Protection
System Protection
Short Circuit Protection for Starting Combinations
|
Technical Specifications
| Specification | Value |
|---|---|
| Brand | SIEMENS |
| Category | Motor Protection Circuit Breakers |
| Series Columns | 3RV5 |
| Thermal Overload Trip Unit Setting Current Range (A) | 18-25 |
| Rated Ultimate Short Circuit Breaking Capacity (KA) | 50 |
| Wiring Method | Screw Terminal Block |
Plain language sourcing guide for SIEMENS 3RV5 Motor Protection Circuit Breaker, 3RV5031-4DA10 11KW 18-25A, 3RV50314DA10
Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.
Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.
Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.
If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.
Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.
Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.
Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.
Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.
For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.
For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.
For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.
| Brand Name: | Siemens | Certification: | ISO9001, CE |
|---|---|---|---|
| Place of Origin: | China | Condition: | New |
| Warranty: | 1 year | Customized sourcing: | available |
What are your strengths?
Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.
What is your estimated delivery time?
Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.
What are your primary product offerings?
Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.
How can I get in touch with you?
Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.
What are your payment terms?
Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.
Feel free to Ask questions
SIEMENS 3RV5 Motor Protection Circuit Breaker, 3RV5031-4DA10 11KW 18-25A, 3RV50314DA10
Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.
For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.
Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.
Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.
- Confirm the complete model number and any suffix printed on the nameplate.
- Share quantity, destination country, preferred shipping method, and target delivery date.
- Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
- Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.
Useful details for a faster quote
- Complete model and part number
- Required quantity and target delivery date
- Nameplate photos, drawings, or old purchase records
- Voltage, signal range, dimensions, or accessory needs
Model matching
We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.
Quality and delivery
Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.
Stock alternatives
For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.
SIEMENS 3RV5 Motor Protection Circuit Breaker, 3RV5031-4DA10 11KW 18-25A, 3RV50314DA10 verification notes
Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.
LEHIY reviews product name, part number, series, label information, and application requirements before shipment.
If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.
For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.
Related Products
Explore More
More In This Category
Trusted partners
We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.