ABB T16 thermal overload relay, T16-2.3 10114920

LEHIY item code: LH-ABB-3053

General Data Operating Time 100% Operating Frequency Without Early Tripping Up to 15 or 60 operations/h at 40% load ratio, with motor starting time not exceeding 1s if motor breaking current is 6xin Installation Mount on the contactor and tighten the screws on the main circuit terminals, or use.

a single mounting kit (35mm) on a DIN rail Positions 1 to 5 Minimum Distance from Other Similar Devices Horizontal None Vertical Not Applicable Minimum Distance from Conductive Plate Horizontal None Vertical As Required Protection Rating IP20 Altitude Above 2000 meters Electromagnetic Compatibility Not Applicable Environmental Data Ambient Air Temperature.

Operation No Derating Open Compensation -25...+60°C Open -25...+60°C Storage -50...+80°C Temperature Compensation Continuous Vibration (Sine) Complies with IEC/EN 60068-2-6 (fc) 3g/3...150Hz Shock (Half-Sine) Complies with IEC/EN 60068-2-27 (ea) 25g/11ms Standards/Directives Product Standards.

IEC/EN 60947–4–1 IEC/EN 60497-5-1 IEC/EN 60947-1 UL 508, CSA 22.2 No.

14 Low Voltage Directive 2006/95/EC: General Data.

Category: Thermal Overload Relay

Rated Operating Voltage U e: Rated Operating Current AC-3 Ie

Quick buying check

This page helps you check ABB T16 thermal overload relay, T16-2.3 10114920 before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

Product Overview

  • Thermal overload relays are economical electromechanical protection devices used in main circuits. They are primarily used to protect motors from overload and phase faults.

  • Starter Combination and Contactor - Starter Settings

Product Features

  • Overload Protection - Trip Level 10

  • Phase Loss Sensitivity

  • Temperature Compensation - 25... +60°C

  • Adjustable Current Setting for Overload Protection

  • Automatic or Manual Reset Optional

  • Suitable for Three-Phase and Single-Phase Applications

  • No Trip Mechanism

  • Status Indication

  • Stop and Test Functions

  • Directly mounted on miniature contactors or block contactors

Technical Specifications

690VAC/DC
T16-Overload Relay
Unless otherwise specified, all data are rated at Ta=40℃
Main Circuit
-2T1-4T2-6T3
Rated Operating Voltage U<sub>e</sub>
Rated Operating Current AC-3 IeSee upper limit of the set range, see table on page 3
Trip Level10
Rated Frequency50/60Hz
Number of Poles3
Isolation Data2T1-4T2-6T3
Rated impulse withstand voltage U<sub>imp</sub>6kV
Rated insulation voltage U<sub>i</sub>690V
Pollution level3
Electrical connection2T1-4T2-6T3
Connection capabilitySolid
1/2x0.75...1.5mm<sup>2</sup>
1/2x1.5...4mm<sup>2</sup>
Stranded Wire1/2x1...4mm<sup>2</sup>
Flexible Coil1/2x0.75...4mm<sup>2</sup>
Insulated Flexible Coil1/2x0.75...4mm<sup>2</sup>
No Flexible Coil1/2x0.75...4mm<sup>2</sup>
Peeling Length12mm
Tightening Torque1.1...1.5Nm
Screw ConnectionM4 (Pozidrive 2)
At DC13 110-120-125V At DC13 250V
T16-Overload Relay
Auxiliary Circuit
-95-96, 97-98
Rated Operating Voltage U<sub>e</sub>600V
Conventional Free Air Thermal Current IthNC, 95-966A
NO, 97-984A
Rated Frequencyd.c., 50/60 Hz
Number of Contacts1NC+1NO
Rated Operating Current
According to IEC/EN 60947-5-1 Usage Category
110-120V in AC15NC, 95-963A
NO, 97-980.75A
220-230-240V in AC15NC, 95-963A
NO, 97-980.75A
440V at AC15NC, 95-960.75A
NO, 97-980.75A
480-500V at AC15NC, 95-960.75A
NO, 97-980.75A
NC, 95-961.25A
NO, 97-981.25A
NC, 95-960.55A
NO, 97-980.55A
NC, 95-960.27A
NO, 97-980.27A
500V at DC13NC, 95-960.15A
NO, 97-980.15A
Minimum switching capacity17V/3mA
Short circuit protection deviceNC, 95-966A, Type gG
NO, 97-984A, Type gG
Isolation Data95-96, 97-98
Rated Impulse Withstand Voltage U<sub>imp</sub>6kV
Rated Insulation Voltage U<sub>i</sub>690V
Contamination Level3
ConnectivitySolid1/2x0.75...4mm<sup>2</sup>
Stranded Wire1/2x0.75...4mm<sup>2</sup>
Flexible Coil1/2x0.75...2.5mm<sup>2</sup>
Insulated Flexible Coil1x0.75...2.5mm<sup>2</sup>
2x0.75...1.5mm<sup>2</sup>
No Flexible Coil1/2x0.75...1mm<sup>2</sup>
1/2x1...2.5mm<sup>2</sup>
Peeling Length9mm
Tightening Torque1...1.5Nm
Screw ConnectionM3(Pozidrive2)
IEC/EN 60497-5-1 IEC/EN 60947-1 UL 508, CSA 22.2 No. 14 Low Voltage Directive 2006/95/EC 2004/108/EC 2002/95/EC
General Data
Operating Time100%
Operating Frequency Without Early TrippingUp to 15 or 60 operations/h at 40% load ratio, with motor starting time not exceeding 1s if
motor breaking current is 6xin
InstallationMount on the contactor and tighten the screws on the main circuit terminals,
or use a single mounting kit (35mm) on a DIN rail
Positions 1 to 5
Minimum Distance from Other Similar DevicesHorizontalNone
VerticalNot Applicable
Minimum Distance from Conductive PlateHorizontalNone
VerticalAs Required
Protection RatingIP20
AltitudeAbove 2000 meters
Electromagnetic CompatibilityNot Applicable
Environmental Data
Ambient Air Temperature
OperationNo Derating Open Compensation-25...+60°C
Open-25...+60°C
Storage-50...+80°C
Temperature CompensationContinuous
Vibration (Sine) Complies with IEC/EN 60068-2-6 (fc)3g/3...150Hz
Shock (Half-Sine) Complies with IEC/EN 60068-2-27 (ea)25g/11ms
Standards/Directives
Product StandardsIEC/EN 60947–4–1
Electromagnetic Compatibility Directive
RoHS Directive

Technical Specifications

SpecificationValue
BrandABB
CategoryThermal Overload Relay
>SeriesT16
Setting Current Range (A)1.7-2.3
Installation MethodPlug-in Type
Applicable ContactorsB9/12/16

Plain language sourcing guide for ABB T16 thermal overload relay, T16-2.3 10114920

Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

Share Article
FacebookTwitterLinkedin
Brand Name:ABBCertification:ISO9001, CE
Place of Origin:ChinaCondition:New
Warranty:1 yearCustomized sourcing:available

What are your strengths?

Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

What is your estimated delivery time?

Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

What are your primary product offerings?

Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

How can I get in touch with you?

Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

What are your payment terms?

Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

Feel free to Ask questions

Replacement support

ABB T16 thermal overload relay, T16-2.3 10114920

Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

  • Confirm the complete model number and any suffix printed on the nameplate.
  • Share quantity, destination country, preferred shipping method, and target delivery date.
  • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
  • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

Useful details for a faster quote

  • Complete model and part number
  • Required quantity and target delivery date
  • Nameplate photos, drawings, or old purchase records
  • Voltage, signal range, dimensions, or accessory needs
Send details

Model matching

We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

Quality and delivery

Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

Stock alternatives

For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

ABB T16 thermal overload relay, T16-2.3 10114920 verification notes

Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

Trusted partners

Trusted partners

We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

Atlas Copco logo
Kobelco logo
Wackerlogo
basf logo
lehiy partners logo
TheLindeGroup-Logo
hitachi logo
foxconn logo
fusheng logo