../../images-webp/706b973bc1cd9b66af660cc3448f91cf.webp

ABB TF thermal overload relay 0.13-142A, TF42-20 10114576

LEHIY item code: LH-ABB-1784

Ambient Air Temperature: Operating

Category: ABB TF thermal overload relay 0.13-142A

Rated Operating Voltage U e: 690VAC

Quick buying check

This page helps you check ABB TF thermal overload relay 0.13-142A, TF42-20 10114576 before you ask for a quote.

Confirm the brand, model number, part number, and quantity. Share a clear nameplate photo when the old item has close variants.

LEHIY can check stock, lead time, packing, shipping documents, and safe replacement options for maintenance orders.

Product Introduction Overview

The TF42 thermal overload relay is an extremely economical and efficient motor protection device for main circuits. It provides reliable protection for motors in case of overload or phase loss. Trip rating: 10A.

  • The thermal overload relay is a three-pole relay with a bimetallic strip trip mechanism. When motor current flows through the bimetallic strip, it heats the strip directly or indirectly.

    In the event of an overload (overcurrent), the bimetallic strip bends due to heat, causing the relay to trip and change the switching position of the contacts (95-96/ 97-98).

  • Manual or automatic reset (optional)

  • Phase loss protection (compliant with IEC 60947-4-1 standard)

  • Reset test function

  • Trip indicator at the front end

  • Ambient temperature compensation

  • Suitable for three-phase and single-phase applications

The F65 thermal overload relay is an extremely cost-effective and efficient motor protection device for main circuits. It provides reliable protection for motors in case of overload or phase loss. Trip rating 10A.

  • The thermal overload relay is a three-stage relay with a bimetallic strip trip mechanism.

  • When motor current flows through the bimetallic strip, it heats the strip directly or indirectly. In the event of an overload (overcurrent), the bimetallic strip bends due to heat, causing the relay to trip and changing the contact switching position (95-96/97-98). Manual or automatic reset (optional) Phase loss protection (compliant with IEC 60947-4-1 standard) Reset test function Phase loss indicator at the front end Ambient temperature compensation Suitable for three-phase and single-phase applications The TF96 thermal overload relay is a highly economical and efficient motor protection device for main circuits, providing reliable protection for motors in case of overload or phase loss. Trip rating: 10A.

    • The thermal overload relay is a three-stage relay with a bimetallic strip tripping device. When motor current flows through the bimetallic strip, it heats the strip directly or indirectly. Once an overload (overcurrent) occurs,

    The bimetallic strip will bend due to the heat, causing the relay to trip and change the switching position of the contacts (95-96/ 97-98).

  • Manual or automatic reset (optional)

  • Phase loss protection (compliant with IEC 60947-4-1 standard)

  • Reset test function

  • Trip indicator at the front end

  • Ambient temperature compensation

  • Suitable for three-phase and single-phase applications

The TF140DU thermal overload relay is an extremely cost-effective and efficient motor protection device for main circuits. It provides reliable protection for motors in case of overload or phase loss. Trip rating 10A.

  • The thermal overload relay is a three-stage relay with a bimetallic strip trip mechanism.

  • When the motor current flows through the bimetallic strip, it heats the strip directly or indirectly. Once an overload (overcurrent) occurs, the bimetallic strip will bend due to the heat, causing the relay to trip and change the switching position of the contacts (95-96/ 97-98).

    • Manual or Automatic Reset (Optional)

    • Phase Loss Protection (Compliant with IEC 60947-4-1 Standard)

    • Reset Test Function - Front-end with Trip Indicator

    • Ambient Temperature Compensation

    • Suitable for Three-Phase and Single-Phase Applications

    Technical Specifications

    Number of Poles 1N.O. + 1N.C. 110-120V N.C., 95-96 3.00A N.O., 97-98
    TF-Overload Relay
    Main Circuit - Usage Characteristics (According to IEC/EN)
    ModelTF42
    StandardIEC/EN60947-4-1,IEC/EN60947-5-1,IEC/EN60947-1
    Rated Operating Voltage U<sub>e</sub>690VAC
    Rated Frequency50/60Hz
    Trip Rating10
    3
    Power supply time100%
    Operating frequency (without early tripping)Maximum 15 times/hour
    Rated impulse withstand voltage U<sub>imp</sub>6kV
    Rated insulation voltage U<sub>i</sub>690VAC
    ModelTF42
    Rated Operating Voltage U<sub>e</sub>600V
    Conventional Free Air Heating Current I<sub>th</sub>N.C.,95-966A
    N.O.,97-984A
    I<sub>e</sub>/Rated Operating Current AC-15
    (According to IEC/EN60947-5-1 Usage Category Standard)
    0.75A
    220-230-240VN.C.,95-963.00A
    N.O.,97-980.75A
    440VN.C.,95-960.75A
    N.O.,97-980.75A
    480-500VN.C.,95-960.75A
    N.O.,97-980.75A
    I<sub>e</sub>/Rated Operating Current DC-13
    (According to IEC/EN60947-5-1 Usage Category Standard)
    24VN.C.,95-961.25A
    N.O.,97-981.25A
    110-120-125VN.C.,95-960.55A
    N.O.,97-980.55A
    250VN.C.,95-960.27A
    N.O.,97-980.27A
    Minimum Switching Capacity17V/3mA
    Short Circuit Protection DeviceN.C.,95-966A, gG Type Fuse
    N.O.,97-984A, gG Type Fuse
    Rated Impulse Withstand Voltage U<sub>imp</sub>6kV
    Rated Insulation Voltage U<sub>i</sub>690V
    25g/11ms 2x 0.75...2.5mm<sup>2</sup>> 2x 0.75...1.5mm<sup>2</sup>> Stretch wire 1x or 2x 0.75...1mm<sup>2</sup> or 1...2.5mm<sup>2</sup>> Stranded wire (according to UL/CSA) 1x or 2x AWG18-12
    TF-Overload Relay
    ModelTF42
    Pollution Degree3
    Sensitive to Phase LossYes
    Ambient Air TemperatureOperatingOpen - with Temperature Compensation-25...+60℃
    Open-25...+60℃
    Storage-50...+80℃
    Ambient Temperature Open CompensationAccording to IEC/EN60947-4-1
    Shock Resistance (Compliant with IEC60068-2-27)
    Vibration Resistance (Compliant with IEC60068-2-6)3g/3...150Hz
    Installation LocationLocation 1-5
    Installation
    Protection RatingEnclosureIP20
    Main Circuit TerminalsIP10
    Electrical Connections
    Main Circuit
    ModelTF42
    (TF42-0.13...TF42-16)
    Wiring CapacityHard Wire1x or 2x0.75...4mm<sup>2</sup>1.5...2.5mm<sup>2</sup> or 2.5...10mm<sup>2</sup>1)
    Strong Wire with Insulating Sheath1x or 2x0.75...4mm<sup>2</sup>2.5...4mm<sup>2</sup> or 4...6mm<sup>2</sup>>
    Stranded wire (according to UL/CSA)1x or 2xAWG18-10AWG14-6
    Strong wire (according to UL/CSA)1x or 2xAWG18-10AWG14-6
    Stripping length12mm
    Tightening Torque1.5-2.5Nm/13...22Ib.in2.5-2.7Nm/22Ib.in
    Connecting ScrewsM4 (M4 2mm)
    <sup>1)</sup>Can connect 2 wires/cables of different diameters, but both must be within the range stated.
    Auxiliary Circuit
    ModelTF42
    Wiring CapacityHard Wire1x or 2x0.75...4mm<sup>2</sup>
    Sprung Wire with Cable Head1x or 2x0.75...2.5mm<sup>2</sup>
    Strong wire (according to UL/CSA)1x or 2xAWG18-12
    Stripping length9mm
    Tightening torque1.1...1.5Nm/9...13Ib.in
    Connecting screwM3 (2mm)
    220-230-240V N.C.,95-96 3.00A
    TF-Overload Relay
    Main Circuit - Usage Characteristics (according to IEC/EN)
    ModelTF65
    StandardIEC/EN60947-1,IEC/EN60947-4-1,IEC/EN60947-5-1
    Rated Operating Voltage U<sub>e</sub>690VAC
    Rated Frequency50/60Hz
    Trip Grade10
    Number of Poles3
    Power Supply Time100%
    Operating Frequency (No Premature Tripping)Maximum 15 times/hour, please refer to "Technical Diagram - Intermittent Cycle Operation"
    imp</sub>8kV
    Rated insulation voltage U<sub>i</sub>690VAC
    Auxiliary circuit (according to IEC/EN)
    ModelTF65
    Rated operating voltage U<sub>e</sub>600V
    th</sub>N.C.,95-966A
    N.O.,97-984A
    Rated frequencyDC,50/60Hz
    Number of poles1N.O.+1N.C.
    N.O.,97-98 0.75A
    N.O.,97-980.75A
    440VN.C.,95-960.75A
    N.O.,97-980.75A
    480-500VN.C.,95-960.75A
    N.O.,97-980.75A
    I<sub>e</sub>/Rated Operating Current DC-13
    (According to IEC/EN60947-5-1 Usage Category Standard)
    24VN.C.,95-961.25A
    N.O.,97-981.25A
    110-120-125VN.C.,95-96
    N.O.,97-980.55A
    250VN.C.,95-960.27A
    N.O.,97-980.27A
    Minimum Switching Capacity17V/3mA
    N.C., 95-966A, gG type fuse
    N.O., 97-984A, gG type fuse
    Rated impulse withstand voltage U<sub>imp</sub>>6kV
    Rated insulation voltage U<sub>i</sub>>690V
    1x 2.5...35mm<sup>2</sup>> Strong wire with cable conduit 1x or 2x 2.5...10mm<sup>2</sup>> 1x 2.5...35mm<sup>2</sup>> <rowspan="2">Strong cord with insulated sheath Tightening Torque 4.0-4.5 Nm/35...40 Ib.in Connecting Screws M6 (Mixed 2) Note: This can connect two wires/cables of different diameters, but both must be within the range described. Strong wire with insulated sheath 18...12
    ModelTF65
    Pollution Degree3
    Sensitive to Phase LossYes
    Ambient Air TemperatureOperatingOpen - With Temperature Compensation-25...+60℃
    Open-25...+60℃
    Storage-50...+80℃
    Ambient temperature open compensation(According to IEC/EN60947-4-1)
    Maximum permissible altitude2000m
    Shock resistance (compliant with IEC60068-2-27)25g/11ms
    Vibration resistant (compliant with IEC 60068-2-6 standard) 3g/3...150Hz
    Installation positionPosition 1
    InstallationInstallate to the contactor and tighten the main circuit terminal; or install to a 35mm DIN rail using a separate mounting kit.
    Protection RatingEnclosureIP20
    Main Circuit TerminalsIP10
    Electrical Connections
    Main Circuit
    ModelTF65
    Wiring CapabilityHard wire 1x or 2x 2.5...16mm<sup>2</sup>>
    1x or 2x2.5...4mm<sup>2</sup>
    1x2.5...35mm<sup>2</sup>
    Strong cord1x or 2x2.5...16mm<sup>2</sup>
    1x2.5...35mm<sup>2</sup>
    Stranded Wire (According to UL/CSA)1xAWG12...2
    2xAWG12...6
    Strong Wire (According to UL/CSA)1xAWG12...2
    2xAWG12...6
    Stripping Length17mm
    Auxiliary Circuit
    ModelTF65
    Wiring CapacityHard Wire1x or 2x0.75...4mm<sup>2</sup>
    Sprung Wire with Cable Head1x or 2x0.75...4mm<sup>2</sup>
    1x0.75...2.5mm<sup>2</sup>
    2x0.75...1.5mm<sup>2</sup>
    Strong wire1x or 2x0.75...1mm<sup>2</sup> or 1...2.5mm<sup>2</sup>
    Stranded wire (according to UL/CSA)1x or 2xAWG
    Strong wire (according to UL/CSA)1x or 2xAWG 18...12
    Stripping length9mm
    Tightening torque1.1...1.5Nm/9...13Ib.in
    Connecting screwM3 (size 2)
    > Rated Frequency 50/60Hz Trip Rating 10 Number of Poles 3 Power Supply Time 100% Operating Frequency (No Premature Tripping) Maximum 15 times/hour Rated Impulse Withstand Voltage U<sub>imp</sub> 8kV
    TF-Overload Relay
    Main Circuit - Usage Characteristics (according to IEC/EN)
    ModelTF96
    StandardIEC/EN60947-1,IEC/EN60947-4-1,IEC/EN60947-5-1
    Rated Operating Voltage U<sub>e</sub>690VAC
    Rated Insulation Voltage U<sub>i</sub>690VAC
    Auxiliary Circuit (according to IEC/EN)
    ModelTF96
    Rated Operating Voltage U<sub>e</sub>600V
    Conventional Free Air Heating Current I<sub>th</sub>N.C.,95-966A
    N.O.,97-984A
    Rated FrequencyDC,50/60Hz
    Number of Poles1N.O.+1N.C.
    I<sub>e</sub>/Rated Operating Current AC-15
    (According to IEC/EN60947-5-1 Usage Category Standard)
    110-120VN.C.,95-963.00A
    N.O.,97-980.75A
    220-230-240VN.C.,95-963.00A
    N.O.,97-980.75A
    440VN.C.,95-960.75A
    N.O.,97-980.75A
    480-500VN.C.,95-960.75A
    N.O.,97-980.75A
    e</sub>/Rated Operating Current DC-13
    (According to IEC/EN60947-5-1 Usage Category Standard)
    24VN.C.,95-961.25A
    N.O.,97-981.25A
    110-120-125VN.C.,95-960.55A
    N.O.,97-980.55A
    250VN.C.,95-960.27A
    N.O.,97-980.27A
    Minimum Switching Capacity17V/3mA
    Short Circuit Protection DeviceN.C.,95-966A, gG type fuse
    N.O.,97-984A, gG type fuse
    Rated impulse withstand voltage U<sub>imp</sub>6kV
    Rated insulation voltage U<sub>i</sub>690V
    1x 6...50mm<sup>2</sup> 1x or 2x 6...35mm<sup>2</sup> 1x 6...50mm<sup>2</sup> Strong wire with insulated sheath 18...12
    ModelTF96
    Pollution Degree3
    Sensitive to Phase LossYes
    Ambient Air TemperatureOperatingOpen - With Temperature Compensation-25...+60℃
    Open-25...+60℃
    Storage-50...+80℃
    Ambient temperature open compensationAccording to IEC/EN 60947-4-1
    Maximum permissible altitude2000m
    Shock resistant (compliant with IEC60068-2-27)25g/11ms
    Installation positionPosition 1
    InstallationInstallate to the contactor and tighten the main circuit terminal; or install to a 35mm DIN rail using a separate mounting kit.
    Protection RatingEnclosureIP20
    Main Circuit TerminalsIP10
    Electrical Connections
    Main Circuit
    ModelTF96
    Wiring CapabilityHard wire 1x or 2x 6...35mm<sup>2</sup>
    Strong wire with cable sheath
    Strong wire with insulating sheath1x or 2x6...16mm<sup>2</sup>
    1x6...50mm<sup>2</sup>
    Strong wire1x or 2x6...35mm<sup>2</sup>
    1x6...50mm<sup>2</sup>
    Stranded wire (according to UL/CSA)1xcolspan="2">AWG8...1
    2xAWG8...3
    Strong wire (according to UL/CSA)1xAWG8...1
    2xAWG8...3
    Stripping length22mm
    Tightening torque
    Connecting ScrewsM8 (Hexagonal)

    Note: Two wires/cables of different diameters can be connected, but both must be within the range described.

    Auxiliary Circuit
    ModelTF96
    Wiring CapacityHard Wire1x or 2x0.75...4mm<sup>2</sup>
    Sprung Wire with Cable Head1x or 2x0.75...4mm<sup>2</sup>
    1x0.75...2.5mm<sup>2</sup>
    2x0.75...1.5mm<sup>2</sup>
    Strong wire1x or 2x0.75...1mm<sup>2</sup> or 1...2.5mm<sup>2</sup>
    Stranded wire (according to UL/CSA)1x or 2xAWG
    Strong wire (according to UL/CSA)1x or 2xAWG 18...12
    Stripping length9mm
    Tightening torque1.1...1.5Nm/9...13Ib.in
    Connecting screwM3 (size 2)
    >
    TF-Overload Relay
    Main Circuit - Usage Characteristics (According to IEC/EN)
    ModelTF140DU
    StandardIEC/EN 60947-1, IEC/EN 60947-4-1, IEC/EN 60947-5-1
    Rated Operating Voltage Ue690 VAC
    Rated FrequencyDC, 50/60 Hz
    Frequency Range0...400 Hz
    Trip Rating10
    Number of Poles3
    Power Supply Time100%
    Operating Frequency (No Premature Trip)Maximum 15 times/hour
    Rated impulse withstand voltage Uimp8kV
    Rated insulation voltage Ui690V
    Auxiliary circuit (according to IEC/EN)
    ModelTF140DU
    Rated operating voltage Ue500 V AC, 440 V DC
    Conventional Free Air Heating Current IthN.C., 95-9610A
    N.O., 97-986A
    Rated FrequencyDC, 50/60Hz
    Number of Poles1N.O.+1N.C.
    N.O.,97-981.50A
    440VN.C.,95-961.00A
    N.O.,97-981.00A
    480-500VN.C.,95-961.00A
    N.O.,97-981.00A
    Ie/Rated Operating Current DC-13
    (According to IEC/EN60947-5-1 Usage Category Standard)
    24VN.C.,95-961.25A
    N.O.,97-981.25A
    60VN.C.,95-960.25A
    N.O.,97-980.25A
    110-120-125VN.C.,95-960.25A
    N.O.,97-980.25A
    250VN.C.,95-960.12A
    N.O.,97-980.04A
    Minimum Switching Capacity17V/3mA
    Short Circuit Protection DeviceN.C.,95-9610A, gG Type Fuse
    N.O.,97-986A, gG Type Fuse
    Rated Impulse Withstand Voltage Uimp
    Rated Insulation Voltage Ui690V
    TF-Overload Relay
    ModelTF140DU
    Pollution Degree3
    Sensitive to Phase LossYes
    Ambient Air TemperatureOperatingOpen - with Temperature Compensation-25...+55℃
    Open-25...+55℃
    Storage-40...+70℃
    Ambient Temperature Open CompensationAccording to IEC/EN60947-4-1
    Shock resistance (compliant with IEC60068-2-27)12g/11ms
    Installation positionPosition 1-5
    InstallationInstallate to the contactor and tighten the main circuit terminals
    Protection levelEnclosure
    Main Circuit TerminalsIP00
    Electrical Connections
    Main Circuit
    ModelTF140DU
    Wiring CapacityHard Wire1x, 2x16…70mm²
    Strong Wire1x, 2x16…70mm²
    Stranded wire (according to UL/CSA)1x or 2xAWG18-2/0
    Strong wire (according to UL/CSA)1x or 2xAWG18-2/0
    Stripping length25mm
    Tightening torque8…10Nm/77..88Ib.in
    Connecting ScrewsM8 (Hexagonal)
    Auxiliary Circuit
    ModelTF104DU
    Wiring CapacityHard Wire1x or 2x0.75...4mm²
    Strong Wire with Cable Sheath1x or 2x0.75...2.5mm²
    Strong wire

    Technical Specifications</

    Plain language sourcing guide for ABB TF thermal overload relay 0.13-142A, TF42-20 10114576

    Start with the full model name. Check the brand name. Check the part number. Check the code on the old unit. These small checks help you avoid a wrong order.

    Take one clear photo of the front label. Take one photo of the side label. If the part has a cable, plug, port, seal, coil, or screen, take a photo of that area too.

    Tell us the quantity you need. Tell us your country. Tell us the date when the plant needs the part. We can then check stock, lead time, safe packing, and the best shipping plan.

    If the exact model is no longer made, do not guess. Send the old model and the use case. LEHIY can compare close options and explain which choice is safer for repair work.

    Use simple order notes. Write the model in one line. Write the quantity in one line. Write the delivery country in one line. This helps our team reply faster.

    Check the old part before removal. Look at the label. Look at the connector. Look at the mounting size. Look at the voltage or pressure rating if it is shown.

    Do not rely on a short nickname for a part. Many industrial items have close versions. A small suffix can change the plug, output, range, or software setting.

    Ask for a stock check if the plant is stopped. Ask for a lead time if the order is planned. Ask for packing photos if the part is fragile or heavy.

    For a replacement order, tell us what failed. Tell us where the part is used. Tell us if an equal model is acceptable. This makes the first answer more useful.

    For repeat orders, send the last invoice, old label, or old packing photo. The same reference can help us match the correct product again.

    For urgent service, keep the message simple. One model, one quantity, one photo, and one delivery target are enough for a fast first check.

    Share Article
    FacebookTwitterLinkedin
    Brand Name:ABBCertification:ISO9001, CE
    Place of Origin:ChinaCondition:New
    Warranty:1 yearCustomized sourcing:available

    What are your strengths?

    Ans. LEHIY specializes in industrial automation and control components, offering fast sourcing, stable quality, and competitive prices for global customers.

    What is your estimated delivery time?

    Ans. Most items ship within 3-7 days. Customized or rare models may take 10-30 working days.

    What are your primary product offerings?

    Ans. Our main products include PLCs, sensors, valves, solenoid valves, actuators, power modules, transmitters, and complete industrial automation solutions.

    How can I get in touch with you?

    Ans. You can reach us anytime via Email, WhatsApp, LinkedIn, or our contact page. Our sales engineers respond quickly and provide technical support when needed.

    What are your payment terms?

    Ans. Standard terms are 50% TT in advance and 50% balance before delivery. We also support Alibaba Trade Assurance and L/C for qualified orders.

    Feel free to Ask questions

    Replacement support

    ABB TF thermal overload relay 0.13-142A, TF42-20 10114576

    Send the brand, model, part number, quantity, nameplate photos, and application requirements. LEHIY will check availability, suitable alternatives, packing details, and delivery options before quoting.

    For discontinued, temporarily unavailable, or configuration-sensitive items, our team can compare the requested model with close variants or compatible replacements for maintenance and spare parts planning.

    Use this page as a practical sourcing note for engineers, buyers, and maintenance teams comparing automation components. Check the model name, brand, LEHIY code, application, and replacement requirements before sending an inquiry.

    Short, clear information helps our team confirm availability faster and reduce back-and-forth communication during urgent maintenance projects.

    • Confirm the complete model number and any suffix printed on the nameplate.
    • Share quantity, destination country, preferred shipping method, and target delivery date.
    • Include photos, drawings, old purchase records, or datasheets when compatible alternatives are acceptable.
    • Ask for stock checking, replacement comparison, packing details, and export documentation before ordering.

    Useful details for a faster quote

    • Complete model and part number
    • Required quantity and target delivery date
    • Nameplate photos, drawings, or old purchase records
    • Voltage, signal range, dimensions, or accessory needs
    Send details

    Model matching

    We review brand, model, part number, nameplate photos, installation environment, and replacement requirements.

    Quality and delivery

    Each order can be checked for authenticity, condition, packing, warranty, shipping method, and delivery schedule.

    Stock alternatives

    For urgent maintenance projects, we can help check stock, compatible alternatives, and fast international shipment.

    ABB TF thermal overload relay 0.13-142A, TF42-20 10114576 verification notes

    Please send the full model number, quantity, target delivery date, and nameplate photos. These details help us check the requested product or a close replacement.

    LEHIY reviews product name, part number, series, label information, and application requirements before shipment.

    If the original model is discontinued or supplied with different accessories, we can explain practical differences before quoting.

    For repeat purchasing, we can help organize related models, replacement parts, shipment schedules, and clear communication for your team.

    Trusted partners

    Trusted partners

    We have collaborated with many well-known enterprises, contributing to their success and establishing a strong reputation as a trusted partner in the industry.

    Atlas Copco logo
    Kobelco logo
    Wackerlogo
    basf logo
    lehiy partners logo
    TheLindeGroup-Logo
    hitachi logo
    foxconn logo
    fusheng logo